Please wait, while we are loading the content...
Please wait, while we are loading the content...
| Content Provider | IEEE Xplore Digital Library |
|---|---|
| Author | Bin Qu Kuhls-Gilcrist, A.T. Ying Huang Weiyuan Wang Cartwright, A.N. Titus, A.H. Bednarek, D.R. Rudin, S. |
| Copyright Year | 2010 |
| Description | Author affiliation: Departments of Electrical Engineering and Biomedical Engineering, University at Buffalo, Buffalo NY 14260 USA (Cartwright, A.N.; Titus, A.H.) || Departments of Physiology and Biophysics, University at Buffalo, Buffalo NY 14214 USA (Weiyuan Wang) || Toshiba Stroke research center, University at Buffalo, Buffalo NY 14214 USA (Kuhls-Gilcrist, A.T.) || Departments of Radiology, Neurosurgery, Physiology and Biophysics, University at Buffalo, Buffalo NY 14214 USA (Bednarek, D.R.) || Departments of Radiology, Mechanical and Aerospace Engineering, Electrical Engineering, Biomedical Engineering, Physiology and Biophysics, and Neurosurgery, University at Buffalo, Buffalo NY 14214 USA (Rudin, S.) || Department of Electrical Engineering, University at Buffalo, Buffalo, NY 14260 USA (Bin Qu; Ying Huang) |
| Abstract | The low electronic noise, high resolution, and good temporal performance of electron-multiplying CCDs (EMCCDs) are ideally suited for applications traditionally served by x-ray image intensifiers. In order to improve an expandable clinical detector's field-of-view and have full control of the system performance, we have successfully built a solid-state x-ray detector. The photon transfer technique was used to quantify the EMCCD quantum performance in terms of sensitivity (or camera gain constant, K), read noise (RN), full-well capacity (FW), and dynamic range (DR). Measured results show the system maintains a K of 11.3 ± 0.9 $e^{−}/DN$ at unit gain, with a read noise of 71.5±6.0 $e^{−}$ rms at gain 1, which decreases proportionally with higher gains. The full well capacity was measured to be 31.3±2.7 $ke^{−},$ providing a dynamic range of 52.8±0.7 dB using the chip manufacturer specified clocking scheme. Similar performance was measured with other commercial camera systems. The manufacturer data sheet indicates a dynamic range of 66 dB is plausible with improved read noise and full well capacity. Different clocking schemes are under investigation to assess their impact on improving performance towards idealized values. EMCCD driver clock voltage levels were adjusted individually to check the influence on quantum performance. The clocks work to transfer charge from the image area to readout amplifier through the storage area, horizontal and multiplication registers. Results indicate that the clock that contributes to lateral overflow drain bias is essential to the system performance in terms of dynamic range and full well capacity. The serial register clocks used for transporting charge stored in the pixels of the memory lines to the output amplifier had the largest effect on RN, while others had less of an impact. Initial adjustment of these clocks resulted in a variability of 16% in the performance of dynamic range, 38% in read noise and 56% in full well capacity. Quantifying the quantum performance provides valuable insight into overall performance and enables optimal adjustment of the clocking scheme. Further improvements are expected. |
| Starting Page | 3438 |
| Ending Page | 3441 |
| File Size | 886374 |
| Page Count | 4 |
| File Format | |
| ISBN | 9781424491063 |
| ISSN | 10957863 |
| e-ISBN | 9781424491056 |
| DOI | 10.1109/NSSMIC.2010.5874445 |
| Language | English |
| Publisher | Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
| Publisher Date | 2010-10-30 |
| Publisher Place | USA |
| Access Restriction | Subscribed |
| Rights Holder | Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
| Subject Keyword | Clocks Noise Dynamic range Gain Registers Photonics Voltage measurement |
| Content Type | Text |
| Resource Type | Article |
National Digital Library of India (NDLI) is a virtual repository of learning resources which is not just a repository with search/browse facilities but provides a host of services for the learner community. It is sponsored and mentored by Ministry of Education, Government of India, through its National Mission on Education through Information and Communication Technology (NMEICT). Filtered and federated searching is employed to facilitate focused searching so that learners can find the right resource with least effort and in minimum time. NDLI provides user group-specific services such as Examination Preparatory for School and College students and job aspirants. Services for Researchers and general learners are also provided. NDLI is designed to hold content of any language and provides interface support for 10 most widely used Indian languages. It is built to provide support for all academic levels including researchers and life-long learners, all disciplines, all popular forms of access devices and differently-abled learners. It is designed to enable people to learn and prepare from best practices from all over the world and to facilitate researchers to perform inter-linked exploration from multiple sources. It is developed, operated and maintained from Indian Institute of Technology Kharagpur.
Learn more about this project from here.
NDLI is a conglomeration of freely available or institutionally contributed or donated or publisher managed contents. Almost all these contents are hosted and accessed from respective sources. The responsibility for authenticity, relevance, completeness, accuracy, reliability and suitability of these contents rests with the respective organization and NDLI has no responsibility or liability for these. Every effort is made to keep the NDLI portal up and running smoothly unless there are some unavoidable technical issues.
Ministry of Education, through its National Mission on Education through Information and Communication Technology (NMEICT), has sponsored and funded the National Digital Library of India (NDLI) project.
| Sl. | Authority | Responsibilities | Communication Details |
|---|---|---|---|
| 1 | Ministry of Education (GoI), Department of Higher Education |
Sanctioning Authority | https://www.education.gov.in/ict-initiatives |
| 2 | Indian Institute of Technology Kharagpur | Host Institute of the Project: The host institute of the project is responsible for providing infrastructure support and hosting the project | https://www.iitkgp.ac.in |
| 3 | National Digital Library of India Office, Indian Institute of Technology Kharagpur | The administrative and infrastructural headquarters of the project | Dr. B. Sutradhar bsutra@ndl.gov.in |
| 4 | Project PI / Joint PI | Principal Investigator and Joint Principal Investigators of the project |
Dr. B. Sutradhar bsutra@ndl.gov.in Prof. Saswat Chakrabarti will be added soon |
| 5 | Website/Portal (Helpdesk) | Queries regarding NDLI and its services | support@ndl.gov.in |
| 6 | Contents and Copyright Issues | Queries related to content curation and copyright issues | content@ndl.gov.in |
| 7 | National Digital Library of India Club (NDLI Club) | Queries related to NDLI Club formation, support, user awareness program, seminar/symposium, collaboration, social media, promotion, and outreach | clubsupport@ndl.gov.in |
| 8 | Digital Preservation Centre (DPC) | Assistance with digitizing and archiving copyright-free printed books | dpc@ndl.gov.in |
| 9 | IDR Setup or Support | Queries related to establishment and support of Institutional Digital Repository (IDR) and IDR workshops | idr@ndl.gov.in |
|
Loading...
|