Please wait, while we are loading the content...
Please wait, while we are loading the content...
| Content Provider | IEEE Xplore Digital Library |
|---|---|
| Author | Frischholz, M. Sarmento, L. Wenzel, M. Aquilina, K. Edwards, R. Coakham, H.B. |
| Copyright Year | 2007 |
| Description | Author affiliation: Universitatsallee, Bremen (Frischholz, M.; Sarmento, L.; Wenzel, M.) |
| Abstract | Patients with hydrocephalus, idiopathic intracranial hypertension and head injury frequently require monitoring of intracranial pressure (ICP) and may need repeated episodes of monitoring months or years apart. The gold standard for measurement of ICP remains the external ventricular catheter. This is a fluid-filled catheter transducer system that allows regular recalibration and correction of zero drift by its position relative to a fixed anatomical reference. It also allows drainage of cerebrospinal fluid (CSF), providing a means of lowering the ICP. Several catheter tip transducer systems are currently in clinical use, including using strain gauges or fiber-optical pressure sensing techniques. In these devices, zero drift and calibration cannot be checked in vivo. All the ICP monitoring devices in current clinical use require a physical connection between the brain and the external environment. This is a source of infection and limits the duration of monitoring. A number of telemetric monitoring devices, in which data is in some way transmitted transcutaneously, have been developed over the last twenty years, but significant technical problems have precluded their use in routine clinical practice. All current ICP monitors are temporary percutaneous implanted devices. Placement of these devices carries significant morbidity, particularly infection. Patients undergoing repeated monitoring require multiple surgical procedures. Apart from decreasing the risk of infection in patients with severe head injury, the clinical value of an accurate telemetric ICP monitoring system which maintains its reliability over a long period of implantation is high. Several neurosurgical conditions require close control of ICP over several years to ensure a satisfactory outcome, such as hydrocephalus treated by a VP shunt or endoscopic third ventriculostomy as well as idiopathic intracranial hypertension. Currently, in these situations, ICP is measured by tapping a ventricular access device or by lumbar puncture; these invasive procedures, often necessary in children, carry a risk of infection. Current ICP monitors show a significant zero drift of the sensor over time which excludes them from being used in long-term implants where recalibration of the sensor is not possible. An implantable telemetric device would overcome many of the problems currently associated with ICP monitoring. Telemetry would allow the ICP to be measured non-invasively at home; symptoms could then be easily evaluated and the necessary adjustments to a programmable shunt, when present, could be performed and confirmed. Utilizing micro- and nanotechnologies as well as advanced packaging technologies, we have developed a fully implantable ICP sensor for long-term use. The sensor implant comprises an absolute capacitive pressure sensor and readout integrated circuit with ultra low power consumption and hence does not require an implanted battery as a power supply, which would otherwise limit the implant's lifetime. The sensor transmits pressure data via inductive coupling to an external device transcutaneously while being powered from outside via radio frequency. The external reader device compensates the absolute pressure data by measuring and subtracting the barometric pressure and displays data representative of intracranial fluid pressure. The implant is encapsulated by several functional layers, ensuring a hermetical sealing while at the same time providing high flexibility. A final biomaterial nano-layer to reduce cell growth and impairment of the mechanical functionality of the sensor is in development. The use of capacitive sensors and the encapsulation scheme guarantees a drift-free performance over time. The implant is designed in a manner so that it can be inserted according to the proven minimally invasive procedures known from current ICP monitors. The measurement tip can be placed either in the ventricle or brain parenchyma while the telemetry unit is located outside the cranial bone directly under the skin for optimal linking to the external unit. Pressure readings can be taken continuously at any time either at home or in hospital. The external read-out device communicates to the clinical periphery or home base station via radio-frequency link. Our device prototypes have successfully passed extensive laboratory tests and are currently tested in vivo in animal trials. |
| Starting Page | 514 |
| Ending Page | 514 |
| File Size | 127425 |
| Page Count | 1 |
| File Format | |
| ISBN | 9781424407873 |
| ISSN | 1557170X |
| DOI | 10.1109/IEMBS.2007.4352337 |
| Language | English |
| Publisher | Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
| Publisher Date | 2007-08-22 |
| Publisher Place | France |
| Access Restriction | Subscribed |
| Rights Holder | Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
| Subject Keyword | Telemetry Intracranial pressure sensors Cranial pressure Patient monitoring Catheters Brain injuries Transducers Hypertension Gold Measurement standards |
| Content Type | Text |
| Resource Type | Article |
| Subject | Signal Processing Biomedical Engineering Health Informatics Computer Vision and Pattern Recognition |
National Digital Library of India (NDLI) is a virtual repository of learning resources which is not just a repository with search/browse facilities but provides a host of services for the learner community. It is sponsored and mentored by Ministry of Education, Government of India, through its National Mission on Education through Information and Communication Technology (NMEICT). Filtered and federated searching is employed to facilitate focused searching so that learners can find the right resource with least effort and in minimum time. NDLI provides user group-specific services such as Examination Preparatory for School and College students and job aspirants. Services for Researchers and general learners are also provided. NDLI is designed to hold content of any language and provides interface support for 10 most widely used Indian languages. It is built to provide support for all academic levels including researchers and life-long learners, all disciplines, all popular forms of access devices and differently-abled learners. It is designed to enable people to learn and prepare from best practices from all over the world and to facilitate researchers to perform inter-linked exploration from multiple sources. It is developed, operated and maintained from Indian Institute of Technology Kharagpur.
Learn more about this project from here.
NDLI is a conglomeration of freely available or institutionally contributed or donated or publisher managed contents. Almost all these contents are hosted and accessed from respective sources. The responsibility for authenticity, relevance, completeness, accuracy, reliability and suitability of these contents rests with the respective organization and NDLI has no responsibility or liability for these. Every effort is made to keep the NDLI portal up and running smoothly unless there are some unavoidable technical issues.
Ministry of Education, through its National Mission on Education through Information and Communication Technology (NMEICT), has sponsored and funded the National Digital Library of India (NDLI) project.
| Sl. | Authority | Responsibilities | Communication Details |
|---|---|---|---|
| 1 | Ministry of Education (GoI), Department of Higher Education |
Sanctioning Authority | https://www.education.gov.in/ict-initiatives |
| 2 | Indian Institute of Technology Kharagpur | Host Institute of the Project: The host institute of the project is responsible for providing infrastructure support and hosting the project | https://www.iitkgp.ac.in |
| 3 | National Digital Library of India Office, Indian Institute of Technology Kharagpur | The administrative and infrastructural headquarters of the project | Dr. B. Sutradhar bsutra@ndl.gov.in |
| 4 | Project PI / Joint PI | Principal Investigator and Joint Principal Investigators of the project |
Dr. B. Sutradhar bsutra@ndl.gov.in Prof. Saswat Chakrabarti will be added soon |
| 5 | Website/Portal (Helpdesk) | Queries regarding NDLI and its services | support@ndl.gov.in |
| 6 | Contents and Copyright Issues | Queries related to content curation and copyright issues | content@ndl.gov.in |
| 7 | National Digital Library of India Club (NDLI Club) | Queries related to NDLI Club formation, support, user awareness program, seminar/symposium, collaboration, social media, promotion, and outreach | clubsupport@ndl.gov.in |
| 8 | Digital Preservation Centre (DPC) | Assistance with digitizing and archiving copyright-free printed books | dpc@ndl.gov.in |
| 9 | IDR Setup or Support | Queries related to establishment and support of Institutional Digital Repository (IDR) and IDR workshops | idr@ndl.gov.in |
|
Loading...
|