Please wait, while we are loading the content...
Please wait, while we are loading the content...
| Content Provider | IEEE Xplore Digital Library | 
|---|---|
| Author | Benner, S.J. Perez, G. Peters, D.W. Hue, K. O'Hagan, P. | 
| Copyright Year | 2011 | 
| Description | Author affiliation: Particle Sizing Systems Port Richey, FL 34668 USA (Hue, K.; O'Hagan, P.) || Confluense, 7277 William Ave., Suite 300, Allentown, PA 18106 USA (Benner, S.J.; Perez, G.; Peters, D.W.) | 
| Abstract | Rotary chemical-mechanical polishing (CMP) tools are widely used for integrated circuit (IC) manufacture. Logic device manufacturing has required CMP for front end (FEOL) and back end (BEOL) processes, such as shallow trench isolation (STI), high-K metal gate (HKMG), dielectric (PMD, ILD, Contact), and interconnect metallization (Cu). Recently, manufacturers of memory ICs adopted Cu metallization which increased their CMP requirements. The normal mode of operation for a rotary CMP tool is one of dilution since fresh slurry is over-fed to a polishing pad that is saturated with spent slurry and process debris in an attempt to achieve pseudo-equilibrium for material removal rates. As a consequence, slurry consumption is significantly higher (by 2X or 3X) than that needed if the spent slurry and process debris were removed in-situ, resulting in a replenishment mode of operation. Changing the CMP tool's mode of operation from dilution to replenishment has been demonstrated to significantly reduce slurry consumption while achieving higher material removal rates (MRR), in agreement with predictions. Rotary CMP tools recycle spent slurry and process debris under the wafer during the polish process. The maximum concentration of process debris occurs at end of polish when one is trying to achieve a high quality surface finish, which is precisely when debris will do the most damage. Much has been reported about the effect of long slurry residence times which result in kinetic decay of the process. However, virtually no data has been published on the impact of process debris residence time on wafer defects, due to the fact that until recently the ability to vary the debris residence time in a controlled manner was not available. Exhausting spent slurry and process by-products in-situ allows removing debris that can cause wafer defects. Several attempts have been made to modify CMP tools and associated components (i.e., slurry delivery arm, pad, wafer retaining ring, etc.) to reduce slurry consumption; however, only one CMP tool modification provides control of both slurry and debris residence times, namely Pad Surface Manager (PSM). PSM, in its simplest mode of operation, can be described as a vacuum cleaner for the pad. Previously published data demonstrated 50% cost savings from reductions in slurry consumption, water consumption, and extended conditioning disk and pad life. This paper will present data that show the impact of PSM on CMP-induced wafer defects. CMP-induced scratches are typically caused by particles, such as agglomerated abrasive, pad debris, or materials of construction (i.e., plastic) larger than 1|im. A flare-up of microscratching can cause both yield loss and reliability issues, bringing a production line to a halt and resulting in premature failure of IC devices in the field. The forces exerted during CMP are more than sufficient to cause particle agglomeration in alumina- or silica-containing slurries. In-situ pad conditioning produces very large particles (e.g., 2 to 200μm) of polyurethane that has been identified as a source of chatter marks, scratches, and microscratches. Accusizer 780 particle size distribution data was acquired for commercially available slurry before and after oxide polishing with samples collected at 10 second intervals using PSM. The mean particle size shifted from 0.6μm to 1.6μm after 10 seconds of polishing and particles larger than 50μm were detected in the used slurry. The number of particles per ml larger than 1μm in the control sample of slurry was 0.13×10. After 10 seconds of polishing with in-situ pad conditioning, the number of particles per ml larger than 1^m increased to $5.7×10^{4},$ more than a 40X increase. After 80 seconds of polishing, the number of particles per ml greater than 1fxm increased to $>33×10^{4},$ a more than 250X increase over the control. As the number of particles per ml larger than 1jxm exceeds $2.0×10^{4},$ the density of microscratches increases exponentially. A typical slurry residence time has been reported to be around 40 seconds. Based on the above results, debris residence time apparently may be considerably longer. Very large particles (i.e., >100μm) from filtered effluent were examined and identified as silica encrusted polyurethane pad particles using energy dispersive spectroscopy (EDS). A 50% reduction in light-point defects on polished thermal oxide wafers was achieved with PSM operated at a moderate vacuum. No attempt was made to differentiate between particles and scratches as the source of light-point defects. | 
| Starting Page | 1 | 
| Ending Page | 4 | 
| File Size | 152106 | 
| Page Count | 4 | 
| File Format | |
| ISBN | 9781612844084 | 
| ISSN | 10788743 | 
| e-ISBN | 9781612844091 | 
| DOI | 10.1109/ASMC.2011.5898183 | 
| Language | English | 
| Publisher | Institute of Electrical and Electronics Engineers, Inc. (IEEE) | 
| Publisher Date | 2011-05-16 | 
| Publisher Place | USA | 
| Access Restriction | Subscribed | 
| Rights Holder | Institute of Electrical and Electronics Engineers, Inc. (IEEE) | 
| Subject Keyword | Slurries Abrasives Effluents Process control Surface treatment Atmospheric measurements | 
| Content Type | Text | 
| Resource Type | Article | 
| Subject | Industrial and Manufacturing Engineering Electronic, Optical and Magnetic Materials Electrical and Electronic Engineering | 
National Digital Library of India (NDLI) is a virtual repository of learning resources which is not just a repository with search/browse facilities but provides a host of services for the learner community. It is sponsored and mentored by Ministry of Education, Government of India, through its National Mission on Education through Information and Communication Technology (NMEICT). Filtered and federated searching is employed to facilitate focused searching so that learners can find the right resource with least effort and in minimum time. NDLI provides user group-specific services such as Examination Preparatory for School and College students and job aspirants. Services for Researchers and general learners are also provided. NDLI is designed to hold content of any language and provides interface support for 10 most widely used Indian languages. It is built to provide support for all academic levels including researchers and life-long learners, all disciplines, all popular forms of access devices and differently-abled learners. It is designed to enable people to learn and prepare from best practices from all over the world and to facilitate researchers to perform inter-linked exploration from multiple sources. It is developed, operated and maintained from Indian Institute of Technology Kharagpur.
Learn more about this project from here.
NDLI is a conglomeration of freely available or institutionally contributed or donated or publisher managed contents. Almost all these contents are hosted and accessed from respective sources. The responsibility for authenticity, relevance, completeness, accuracy, reliability and suitability of these contents rests with the respective organization and NDLI has no responsibility or liability for these. Every effort is made to keep the NDLI portal up and running smoothly unless there are some unavoidable technical issues.
 
					 
					Ministry of Education, through its National Mission on Education through Information and Communication Technology (NMEICT), has sponsored and funded the National Digital Library of India (NDLI) project.
| Sl. | Authority | Responsibilities | Communication Details | 
|---|---|---|---|
| 1 | Ministry of Education (GoI), Department of Higher Education | Sanctioning Authority | https://www.education.gov.in/ict-initiatives | 
| 2 | Indian Institute of Technology Kharagpur | Host Institute of the Project: The host institute of the project is responsible for providing infrastructure support and hosting the project | https://www.iitkgp.ac.in | 
| 3 | National Digital Library of India Office, Indian Institute of Technology Kharagpur | The administrative and infrastructural headquarters of the project | Dr. B. Sutradhar bsutra@ndl.gov.in | 
| 4 | Project PI / Joint PI | Principal Investigator and Joint Principal Investigators of the project | Dr. B. Sutradhar  bsutra@ndl.gov.in Prof. Saswat Chakrabarti will be added soon | 
| 5 | Website/Portal (Helpdesk) | Queries regarding NDLI and its services | support@ndl.gov.in | 
| 6 | Contents and Copyright Issues | Queries related to content curation and copyright issues | content@ndl.gov.in | 
| 7 | National Digital Library of India Club (NDLI Club) | Queries related to NDLI Club formation, support, user awareness program, seminar/symposium, collaboration, social media, promotion, and outreach | clubsupport@ndl.gov.in | 
| 8 | Digital Preservation Centre (DPC) | Assistance with digitizing and archiving copyright-free printed books | dpc@ndl.gov.in | 
| 9 | IDR Setup or Support | Queries related to establishment and support of Institutional Digital Repository (IDR) and IDR workshops | idr@ndl.gov.in | 
| 
                                Loading...
                             |