Please wait, while we are loading the content...
Please wait, while we are loading the content...
| Content Provider | World Health Organization (WHO)-Global Index Medicus |
|---|---|
| Author | Deffieux, Xavier Letouzey, Vincent Savary, Denis Sentilhes, Loïc Agostini, Aubert Mares, Pierre Pierre, Fabrice |
| Organization | French College of Obstetrics and Gynecology (CNGOF) |
| Description | Country affiliation: France Author Affiliation: Deffieux X ( AP-HP, Hôpital Antoine Béclère, Service de Gynécologie-Obstétrique et Médecine de la Reproduction, Clamart, F-92141, France. xavier.deffieux@abc.aphp.fr) |
| Abstract | The objective of the study was to provide guidelines for clinical practice from the French College of Obstetrics and Gynecology (CNGOF), based on the best evidence available, concerning adverse events related to surgical procedures involving the use of prosthetic meshes. French and English-language articles from Medline, PubMed, and the Cochrane Database were searched, using key words (mesh; pelvic organ prolapse; cystocele; rectocele; uterine prolapse; complications; adverse event; sacral colpopexy; extrusion; infection). As with any surgery, recommendations include perioperative smoking cessation (Expert opinion) and compliance with the prevention of nosocomial infections (regulatory recommendation). There is no evidence to recommend routine local or systemic estrogen therapy before or after prolapse surgery using mesh, regardless of the surgical approach (Grade C). Antibiotic prophylaxis is recommended, regardless of the approach (Expert opinion). It is recommended to check for pre-operative urinary tract infection and treat it (Expert opinion). The first procedure should be undertaken under the guidance of a surgeon experienced in the relevant technique (Grade C). It is recommended not to place a non-absorbable synthetic mesh into the rectovaginal septum when a rectal injury occurs (Expert opinion). Placement of a non-absorbable synthetic mesh into the vesicovaginal septum may be considered after suturing of a bladder injury if the suture is considered to be satisfactory (Expert opinion). If a synthetic mesh is placed by vaginal route, it is recommended to use a macroporous polypropylene monofilament mesh (Grade B). It is recommended not to use polyester mesh for vaginal surgery (Grade B). It is permissible to perform hysterectomy associated with the placement of a non-absorbable synthetic mesh placed by the vaginal route but this is not routinely recommended (Expert opinion). It is recommended to minimize the extent of the colpectomy (Expert opinion). The laparoscopic approach is recommended for sacral colpopexy (Expert opinion). It is recommended not to place and suture meshes by the vaginal route when a sacral colpopexy is performed (Grade B). It is recommended not to use silicone-coated polyester, porcine dermis, fascia lata, and polytetrafluoroethylene meshes (Grade B). It is recommended to use polyester (without silicone coating) or polypropylene meshes (Grade C). Suture of the meshes to the promontory can be performed using thread/needle or tacks (Grade C). Peritonization is recommended to cover the meshes (Grade C). If hysterectomy is required, it is recommended to perform a subtotal hysterectomy (Expert opinion). Implementation of this guideline should decrease the prevalence of complications related to surgical procedures involving the use of prosthetic meshes. |
| File Format | HTM / HTML |
| ISSN | 03012115 |
| Issue Number | 2 |
| Volume Number | 165 |
| e-ISSN | 18727654 |
| Journal | European Journal of Obstetrics & Gynecology and Reproductive Biology |
| Language | English |
| Publisher | Elsevier |
| Publisher Date | 2012-12-01 |
| Publisher Place | Ireland |
| Access Restriction | One Nation One Subscription (ONOS) |
| Subject Keyword | Discipline Obstetrics Discipline Gynecology Cross Infection Prevention & Control Pelvic Organ Prolapse Surgery Postoperative Complications Surgical Mesh Adverse Effects Adult Antibiotic Prophylaxis Female Humans Polypropylenes Prostheses And Implants Surgical Procedures, Operative Education Uterine Prolapse Journal Article Review |
| Content Type | Text |
| Resource Type | Article |
| Subject | Reproductive Medicine Obstetrics and Gynecology |
National Digital Library of India (NDLI) is a virtual repository of learning resources which is not just a repository with search/browse facilities but provides a host of services for the learner community. It is sponsored and mentored by Ministry of Education, Government of India, through its National Mission on Education through Information and Communication Technology (NMEICT). Filtered and federated searching is employed to facilitate focused searching so that learners can find the right resource with least effort and in minimum time. NDLI provides user group-specific services such as Examination Preparatory for School and College students and job aspirants. Services for Researchers and general learners are also provided. NDLI is designed to hold content of any language and provides interface support for 10 most widely used Indian languages. It is built to provide support for all academic levels including researchers and life-long learners, all disciplines, all popular forms of access devices and differently-abled learners. It is designed to enable people to learn and prepare from best practices from all over the world and to facilitate researchers to perform inter-linked exploration from multiple sources. It is developed, operated and maintained from Indian Institute of Technology Kharagpur.
Learn more about this project from here.
NDLI is a conglomeration of freely available or institutionally contributed or donated or publisher managed contents. Almost all these contents are hosted and accessed from respective sources. The responsibility for authenticity, relevance, completeness, accuracy, reliability and suitability of these contents rests with the respective organization and NDLI has no responsibility or liability for these. Every effort is made to keep the NDLI portal up and running smoothly unless there are some unavoidable technical issues.
Ministry of Education, through its National Mission on Education through Information and Communication Technology (NMEICT), has sponsored and funded the National Digital Library of India (NDLI) project.
| Sl. | Authority | Responsibilities | Communication Details |
|---|---|---|---|
| 1 | Ministry of Education (GoI), Department of Higher Education |
Sanctioning Authority | https://www.education.gov.in/ict-initiatives |
| 2 | Indian Institute of Technology Kharagpur | Host Institute of the Project: The host institute of the project is responsible for providing infrastructure support and hosting the project | https://www.iitkgp.ac.in |
| 3 | National Digital Library of India Office, Indian Institute of Technology Kharagpur | The administrative and infrastructural headquarters of the project | Dr. B. Sutradhar bsutra@ndl.gov.in |
| 4 | Project PI / Joint PI | Principal Investigator and Joint Principal Investigators of the project |
Dr. B. Sutradhar bsutra@ndl.gov.in Prof. Saswat Chakrabarti will be added soon |
| 5 | Website/Portal (Helpdesk) | Queries regarding NDLI and its services | support@ndl.gov.in |
| 6 | Contents and Copyright Issues | Queries related to content curation and copyright issues | content@ndl.gov.in |
| 7 | National Digital Library of India Club (NDLI Club) | Queries related to NDLI Club formation, support, user awareness program, seminar/symposium, collaboration, social media, promotion, and outreach | clubsupport@ndl.gov.in |
| 8 | Digital Preservation Centre (DPC) | Assistance with digitizing and archiving copyright-free printed books | dpc@ndl.gov.in |
| 9 | IDR Setup or Support | Queries related to establishment and support of Institutional Digital Repository (IDR) and IDR workshops | idr@ndl.gov.in |
|
Loading...
|