Loading...
Please wait, while we are loading the content...
Similar Documents
Clinical and angiographic predictors of luminal changes beyond 6 months after implantation of thicker strut coronary stents.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Sadamatsu, Kenji Tashiro, H. Yutaka Tanaka, Eriko Yamamoto, Kunihiko |
| Copyright Year | 2005 |
| Abstract | BACKGROUND Late luminal changes beyond 6 months after thicker strut stent implantation have not been fully elucidated. The purpose of this study was to clarify the clinical and angiographic predictors of late changes in minimal lumen diameter (MLD) after 6-month follow-up of stenting. METHODS AND RESULTS Fifty-one lesions from 44 patients who underwent successfully S670/660 stent (Medtronic Vascular, Santa Rosa, CA, USA) implantations without target lesion revascularization were studied at 6-month follow-up and coronary angiography was repeated after the follow-up. Late luminal loss beyond 6 months after stenting significantly correlated with late loss (r=-0.42, p=0.0025) and MLD (r=0.28, p=0.047) at 6-month follow-up. On multivariate analysis, age (p=0.005), diabetes mellitus (p=0.002), hyperlipidemia (p=0.023), smoking (p=0.015), bifurcation lesion (p=0.018), small stent diameter (p=0.001) and MLD at 6-month follow-up (p<0.001) were identified as independent predictors of late luminal loss. CONCLUSIONS This study demonstrated that older age, diabetes mellitus, hyperlipidemia, smoking and small stent diameter (<3.0 mm) were associated with late luminal loss beyond 6 months after stenting, and that a bifurcation lesion and small lumen diameter at 6 months were associated with late luminal recovery. |
| Starting Page | 426 |
| Ending Page | 431 |
| Page Count | 6 |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | https://www.jstage.jst.go.jp/article/circj/69/1/69_1_35/_pdf/-char/en |
| PubMed reference number | 15635199v1 |
| Volume Number | 69 |
| Issue Number | 1 |
| Journal | Circulation journal : official journal of the Japanese Circulation Society |
| Language | English |
| Access Restriction | Open |
| Subject Keyword | Cerebrovascular Disorders Coronary angiography Diabetes Mellitus Diameter (qualifier value) Hyperlipidemia Inner Diameter Late Lumen Loss Measurement Lipoid nephrosis Patients Phenobarbital STENT, CORONARY Smoke Stent Device Component Stent, device Structure of lumen of body system Weight-Loss Agents angiogram hearing impairment |
| Content Type | Text |
| Resource Type | Article |