Please wait, while we are loading the content...
Please wait, while we are loading the content...
| Content Provider | World Health Organization (WHO)-Global Index Medicus |
|---|---|
| Author | Zhang, Stanley Weihua Jian, Wenying Sullivan, Sheryl Sankaran, Banu Edom, Richard W. Weng, Naidong Sharkey, David |
| Description | Author Affiliation: Zhang SW ( Ortho Clinical Diagnostics, Johnson & Johnson, 1001 Route 202 North, Raritan, NJ 08869, United States. Electronic address: wzhang7@its.jnj.com.); Jian W ( Janssen Research and Development, Johnson & Johnson, 1400 McKean Road, Spring House, PA 19477, United States.); Sullivan S ( Ortho Clinical Diagnostics, Johnson & Johnson, 1001 Route 202 North, Raritan, NJ 08869, United States.); Sankaran B ( Ortho Clinical Diagnostics, Johnson & Johnson, 1001 Route 202 North, Raritan, NJ 08869, United States.); Edom RW ( Janssen Research and Development, Johnson & Johnson, 1400 McKean Road, Spring House, PA 19477, United States.); Weng N ( Janssen Research and Development, Johnson & Johnson, 1400 McKean Road, Spring House, PA 19477, United States.); Sharkey D ( Ortho Clinical Diagnostics, Johnson & Johnson, 1001 Route 202 North, Raritan, NJ 08869, United States.) |
| Abstract | Vitamin D deficiency is increasing in the general population and has become a serious public health risk globally. As a reliable clinical indicator of vitamin status, 25 hydroxyvitamin D (25(OH)D) has been measured by various methods. However, the accuracy of these measurements has been the subject of considerable debate. Here, we report the development and validation of a liquid chromatography-triple quadrupole mass spectrometry based method for the quantification of 25(OH)D2 and 25(OH)D3 in human serum and plasma samples. Samples were first processed by protein precipitation to release the analytes from the vitamin D binding protein (DBP), followed by a liquid-liquid extraction procedure. Analysis was performed on an LC-MS/MS system which utilized an AB Sciex API 3000 mass spectrometer. A six point calibration curve ranging from 2.5 to 100ng/mL was established for both 25(OH)D2 and 25(OH)D3. A complete method validation was conducted, including intra- and inter-assay accuracy and precision, LLOQ, dilution QC, specificity, recovery, matrix effect, and a thorough stability profile of stock solutions and QC samples. Matching samples of serum and plasma (containing either heparin or EDTA anticoagulant) generated from the same blood samples were tested, and no significant differences in 25(OH)D2 and 25(OH)D3 concentrations were found in these sample matrices. In method comparison, we analyzed 10 serum samples obtained from the Vitamin D External Quality Assessment Scheme (DEQAS), and the total 25(OH)D concentrations measured by our method were very close to the LC-MS/MS Method Mean values provided by DEQAS (average 0.17% bias, R(2)=0.99). However, comparison with the DiaSorin Liaison 25(OH)D TOTAL Assay demonstrated limited correlation between these two methods (R(2)=0.54). In general, concentrations measured by our LC-MS/MS method were roughly 9% higher than those measured by the DiaSorin Liaison assay. The correlation with DiaSorin Liaison measurement was better for samples in the lower concentration range. In summary, we developed and validated an LC-MS/MS based method that can be reliably applied in routine quantification of 25(OH)D2 and 25(OH)D3 in human serum and plasma samples. This method is not suitable for pediatric determinations due to the potential interference of 3-epi 25(OH)D3. |
| File Format | HTM / HTML |
| ISSN | 15700232 |
| Volume Number | 961 |
| e-ISSN | 1873376X |
| Journal | Journal of Chromatography B |
| Language | English |
| Publisher | Elsevier |
| Publisher Date | 2014-06-15 |
| Publisher Place | Netherlands |
| Access Restriction | One Nation One Subscription (ONOS) |
| Subject Keyword | Discipline Analytical Chemistry 25-hydroxyvitamin D 2 Blood Calcifediol Animals Child Cholecalciferol Drug Stability Female Horses Humans Limit Of Detection Liquid-liquid Extraction Male Reproducibility Of Results Sensitivity And Specificity Tandem Mass Spectrometry Methods Comparative Study Journal Article Validation Studies |
| Content Type | Text |
| Resource Type | Article |
| Subject | Cell Biology Medicine Analytical Chemistry Clinical Biochemistry Biochemistry |
National Digital Library of India (NDLI) is a virtual repository of learning resources which is not just a repository with search/browse facilities but provides a host of services for the learner community. It is sponsored and mentored by Ministry of Education, Government of India, through its National Mission on Education through Information and Communication Technology (NMEICT). Filtered and federated searching is employed to facilitate focused searching so that learners can find the right resource with least effort and in minimum time. NDLI provides user group-specific services such as Examination Preparatory for School and College students and job aspirants. Services for Researchers and general learners are also provided. NDLI is designed to hold content of any language and provides interface support for 10 most widely used Indian languages. It is built to provide support for all academic levels including researchers and life-long learners, all disciplines, all popular forms of access devices and differently-abled learners. It is designed to enable people to learn and prepare from best practices from all over the world and to facilitate researchers to perform inter-linked exploration from multiple sources. It is developed, operated and maintained from Indian Institute of Technology Kharagpur.
Learn more about this project from here.
NDLI is a conglomeration of freely available or institutionally contributed or donated or publisher managed contents. Almost all these contents are hosted and accessed from respective sources. The responsibility for authenticity, relevance, completeness, accuracy, reliability and suitability of these contents rests with the respective organization and NDLI has no responsibility or liability for these. Every effort is made to keep the NDLI portal up and running smoothly unless there are some unavoidable technical issues.
Ministry of Education, through its National Mission on Education through Information and Communication Technology (NMEICT), has sponsored and funded the National Digital Library of India (NDLI) project.
| Sl. | Authority | Responsibilities | Communication Details |
|---|---|---|---|
| 1 | Ministry of Education (GoI), Department of Higher Education |
Sanctioning Authority | https://www.education.gov.in/ict-initiatives |
| 2 | Indian Institute of Technology Kharagpur | Host Institute of the Project: The host institute of the project is responsible for providing infrastructure support and hosting the project | https://www.iitkgp.ac.in |
| 3 | National Digital Library of India Office, Indian Institute of Technology Kharagpur | The administrative and infrastructural headquarters of the project | Dr. B. Sutradhar bsutra@ndl.gov.in |
| 4 | Project PI / Joint PI | Principal Investigator and Joint Principal Investigators of the project |
Dr. B. Sutradhar bsutra@ndl.gov.in Prof. Saswat Chakrabarti will be added soon |
| 5 | Website/Portal (Helpdesk) | Queries regarding NDLI and its services | support@ndl.gov.in |
| 6 | Contents and Copyright Issues | Queries related to content curation and copyright issues | content@ndl.gov.in |
| 7 | National Digital Library of India Club (NDLI Club) | Queries related to NDLI Club formation, support, user awareness program, seminar/symposium, collaboration, social media, promotion, and outreach | clubsupport@ndl.gov.in |
| 8 | Digital Preservation Centre (DPC) | Assistance with digitizing and archiving copyright-free printed books | dpc@ndl.gov.in |
| 9 | IDR Setup or Support | Queries related to establishment and support of Institutional Digital Repository (IDR) and IDR workshops | idr@ndl.gov.in |
|
Loading...
|