Please wait, while we are loading the content...
Please wait, while we are loading the content...
| Content Provider | World Health Organization (WHO)-Global Index Medicus |
|---|---|
| Author | Beamer, Brandon S. Morgan, Jordan H. Barr, Christopher Weaver, Michael J. Vrahas, Mark S. |
| Description | Author Affiliation: Beamer BS ( Department of Orthopaedic Surgery, Harvard Medical School, Brigham and Women's Hospital, Boston, MA, USA, bbeamer@partners.org.) |
| Abstract | BACKGROUND: The success of THA largely depends on correct placement of the individual components. Traditionally, these have been placed freehand using anatomic landmarks, but studies have shown poor accuracy with this method. QUESTIONS/PURPOSES: Specifically, we asked (1) does using fluoroscopy lead to more accurate and greater likelihood of cup placement with the Lewinnek safe zone than does freehand cup placement; (2) is there a learning curve associated with the use of fluoroscopy for cup placement; (3) does the use of fluoroscopy increase operative time; and (4) is there a difference in leg length discrepancy between freehand and fluoroscopic techniques? METHODS: This series consisted of 109 consecutive patients undergoing primary THA, conversion of a previous hip surgery to THA, and revision THA during a 24-month period. No patients were excluded from analysis during this time. The first 52 patients had cups placed freehand, and then the next 57 patients had acetabular components placed using fluoroscopy; the analysis began with the first patient treated using fluoroscopy, to include our initial experience with the technique. The abduction, version, and limb length discrepancy were measured on 6-week postoperative pelvic radiographs obtained with the patient in the supine position. Operative time, sex, age, BMI, diagnosis, operative side, and femoral head size were recorded as possible confounders. RESULTS: Cups inserted freehand were placed in the ideal range of abduction (30°-45°) and anteversion (5°-25°) 44% of the time. With fluoroscopy, placement in the Lewinnek safe zone for both measures significantly increased to 65%. The odds of placing the cup in the Lewinnek safe zone for abduction and version were 2.3 times greater with the use of fluoroscopy (95% CI, 1.2-5.0; p = 0.03). Patients undergoing primary THAs (32 freehand, 35 C-arm) had cup placement in the safe zone for abduction and version 44% of the time freehand and 57% of the time with fluoroscopy, which failed to reach statistical significance. There was no difference in operative time, patient age, sex, operative side, diagnosis, limb length discrepancy, or femoral head size between the two groups. CONCLUSIONS: The use of fluoroscopy to directly observe pelvic position and acetabular component placement increased the success of placement in the Lewinnek safe zone in this cohort of patients having complex and primary THAs. This is a simple, low-cost, and quick method for increasing successful acetabular component alignment. The study population included a large proportion of patients having complex THAs, and further validation of this technique in patients undergoing straightforward, primary THAs needs to be done to understand if similar gains in accuracy for component placement can be expected in that group. LEVEL OF EVIDENCE: Level III, therapeutic study. See the Instructions for Authors for a complete description of levels of evidence. |
| File Format | HTM / HTML |
| ISSN | 0009921X |
| e-ISSN | 15281132 |
| DOI | 10.1007/s11999-014-3944-8 |
| Journal | Clinical Orthopaedics and Related Researchtextregistered |
| Issue Number | 12 |
| Volume Number | 472 |
| Language | English |
| Publisher | Springer |
| Publisher Date | 2014-12-01 |
| Publisher Place | United States |
| Access Restriction | Open |
| Subject Keyword | Discipline Orthopaedics Acetabulum Surgery Arthroplasty, Replacement, Hip Instrumentation Hip Joint Hip Prosthesis Radiography, Interventional Physiopathology Anatomic Landmarks Adverse Effects Biomechanical Phenomena Fluoroscopy Leg Length Inequality Etiology Length Of Stay Operative Time Prosthesis Design Range Of Motion, Articular Retrospective Studies Time Factors |
| Content Type | Text |
| Resource Type | Article |
| Subject | Orthopedics and Sports Medicine Surgery Sports Science |
National Digital Library of India (NDLI) is a virtual repository of learning resources which is not just a repository with search/browse facilities but provides a host of services for the learner community. It is sponsored and mentored by Ministry of Education, Government of India, through its National Mission on Education through Information and Communication Technology (NMEICT). Filtered and federated searching is employed to facilitate focused searching so that learners can find the right resource with least effort and in minimum time. NDLI provides user group-specific services such as Examination Preparatory for School and College students and job aspirants. Services for Researchers and general learners are also provided. NDLI is designed to hold content of any language and provides interface support for 10 most widely used Indian languages. It is built to provide support for all academic levels including researchers and life-long learners, all disciplines, all popular forms of access devices and differently-abled learners. It is designed to enable people to learn and prepare from best practices from all over the world and to facilitate researchers to perform inter-linked exploration from multiple sources. It is developed, operated and maintained from Indian Institute of Technology Kharagpur.
Learn more about this project from here.
NDLI is a conglomeration of freely available or institutionally contributed or donated or publisher managed contents. Almost all these contents are hosted and accessed from respective sources. The responsibility for authenticity, relevance, completeness, accuracy, reliability and suitability of these contents rests with the respective organization and NDLI has no responsibility or liability for these. Every effort is made to keep the NDLI portal up and running smoothly unless there are some unavoidable technical issues.
Ministry of Education, through its National Mission on Education through Information and Communication Technology (NMEICT), has sponsored and funded the National Digital Library of India (NDLI) project.
| Sl. | Authority | Responsibilities | Communication Details |
|---|---|---|---|
| 1 | Ministry of Education (GoI), Department of Higher Education |
Sanctioning Authority | https://www.education.gov.in/ict-initiatives |
| 2 | Indian Institute of Technology Kharagpur | Host Institute of the Project: The host institute of the project is responsible for providing infrastructure support and hosting the project | https://www.iitkgp.ac.in |
| 3 | National Digital Library of India Office, Indian Institute of Technology Kharagpur | The administrative and infrastructural headquarters of the project | Dr. B. Sutradhar bsutra@ndl.gov.in |
| 4 | Project PI / Joint PI | Principal Investigator and Joint Principal Investigators of the project |
Dr. B. Sutradhar bsutra@ndl.gov.in Prof. Saswat Chakrabarti will be added soon |
| 5 | Website/Portal (Helpdesk) | Queries regarding NDLI and its services | support@ndl.gov.in |
| 6 | Contents and Copyright Issues | Queries related to content curation and copyright issues | content@ndl.gov.in |
| 7 | National Digital Library of India Club (NDLI Club) | Queries related to NDLI Club formation, support, user awareness program, seminar/symposium, collaboration, social media, promotion, and outreach | clubsupport@ndl.gov.in |
| 8 | Digital Preservation Centre (DPC) | Assistance with digitizing and archiving copyright-free printed books | dpc@ndl.gov.in |
| 9 | IDR Setup or Support | Queries related to establishment and support of Institutional Digital Repository (IDR) and IDR workshops | idr@ndl.gov.in |
|
Loading...
|