Loading...
Please wait, while we are loading the content...
About the Authors.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Bryant, Monica Fawzy |
| Copyright Year | 2017 |
| Abstract | A 55-year-old man with a history of multiple gunshot wounds complicated by dense adhesions from several previous episodes of abdominal surgery presented with persistent nausea/vomiting. His past medical history included a chronic enterocutaneous fistula, which had been closed with an atrial septal occluder. Additionally, he had had vomiting due to a duodenal stricture secondary to adhesions and he had undergone endoscopic ultrasound (EUS)-guided gastrojejunostomy with a lumen-apposing metal stent (LAMS). This had been complicated by stent misdeployment that required placement of a second tandem LAMS. The patient had reported improvement in his quality of life after closure of the enterocutaneous fistula and weight gain after undergoing the gastrojejunostomy. However, 6 months later, he developed recurrent nausea/vomiting. During endoscopy, the previously placed 15-mm LAMS had evidence of tissue ingrowth through the eroded plastic covering, which was causing there to be a smaller gastrojejunostomy lumen. The stent was dilated with a 15-mm controlled radial expansion balloon, which permitted the endoscope to be advanced into the small intestine. However, the LAMS could not be removed because of tissue ingrowth. Therefore, argon plasma coagulation (APC) was used to break the mesh of the stent (▶Fig. 1). A 20-mm LAMSwas then deployed across the previous stent under endoscopic and fluoroscopic guidance (▶Video1). The new stent was anchored with a 7-Fr ×15-cm plastic double-pigtail stent. Following placement of the 20-mm LAMS, the patient’s symptoms of nausea and vomiting improved considerably. EUS-guided gastrojejunostomy has previously been shown to be successful for the management of gastric outlet obstruction secondary to benign and malignant disease [1, 2]. Previous studies have utilized LAMS of 10mm and 15mm in diameter. Nonetheless, the smaller diameter can lead to stent obstruction, either by tissue ingrowth or food. With the advent of the 20-mm LAMS, patients can now undergo successful larger diameter gastrojejunostomy. Future studies will be needed to determine whether the larger lumen will improve the overall nutrition and health of these patients. E-Videos |
| Starting Page | iii |
| Ending Page | iv |
| Page Count | 2 |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | https://www.thieme-connect.com/products/ejournals/pdf/10.1055/a-0640-2630.pdf |
| Alternate Webpage(s) | https://www.americanbar.org/content/dam/aba-cms-dotorg/products/inv/book/303230991/5630144_author.pdf |
| Alternate Webpage(s) | https://www.thieme-connect.de/products/ejournals/pdf/10.1055/a-0640-2630.pdf |
| PubMed reference number | 29211973v1 |
| Alternate Webpage(s) | https://doi.org/10.1177/1529100617743455 |
| DOI | 10.1177/1529100617743455 |
| Journal | Psychological science in the public interest : a journal of the American Psychological Society |
| Volume Number | 18 |
| Issue Number | 2 |
| Language | English |
| Access Restriction | Open |
| Subject Keyword | Argon Plasma Coagulation Cholestasis Closure Cytochrome P-450 CYP1A1 Diameter (qualifier value) Duodenum Endoscopes Endoscopic Ultrasound Enterocutaneous Fistula Esophageal Stenosis Gastrojejunostomy Gunshot wound Heart Atrium Heparin, Low-Molecular-Weight Large Obstruction Patients Postoperative Nausea and Vomiting Pyloric Stenosis Septal Occluder Device Small Intestinal Wall Tissue Stent Device Component Stent, device Structure of lumen of body system Tissue Adhesions Units Of Measure - lumen Used Quit Cigarette Smoking Videos Ventricular Septal Defects malignant disease |
| Content Type | Text |