Loading...
Please wait, while we are loading the content...
Similar Documents
Fully automated deconvolution method for on-line analysis of time-resolved fluorescence spectroscopy data based on an iterative Laguerre expansion technique.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Dabir, Aditi Sandeep Trivedi, Chintan A. Ryu, Yeontack Pande, Paritosh Jo, Javier A. |
| Copyright Year | 2009 |
| Abstract | Time-resolved fluorescence spectroscopy (TRFS) is a powerful analytical tool for quantifying the biochemical composition of organic and inorganic materials. The potential of TRFS for tissue diagnosis has been recently demonstrated. To facilitate the translation of TRFS to the clinical arena, algorithms for online TRFS data analysis are essential. A fast model-free TRFS deconvolution algorithm based on the Laguerre expansion method has previously been introduced. One limitation of this method, however, is the need to heuristically select two parameters that are crucial for the accurate estimation of the fluorescence decay: the Laguerre parameter alpha and the expansion order. Here, a new implementation of the Laguerre deconvolution method is introduced, in which a nonlinear least-square optimization of the Laguerre parameter alpha is performed, and the optimal expansion order is selected based on a minimum description length criterion (MDL). In addition, estimation of the zero-time delay between the recorded instrument response and fluorescence decay is also performed based on normalized mean square error criterion (NMSE). The method is validated on experimental data from fluorescence lifetime standards, endogenous tissue fluorophores, and human tissue. The proposed automated Laguerre deconvolution method will facilitate online applications of TRFS, such as real-time clinical tissue diagnosis. |
| Starting Page | 024030 |
| Ending Page | 024030 |
| Page Count | 1 |
| File Format | PDF HTM / HTML |
| DOI | 10.1117/1.3103342 |
| PubMed reference number | 19405759 |
| Journal | Medline |
| Volume Number | 14 |
| Issue Number | 2 |
| Alternate Webpage(s) | http://biomed.tamu.edu/LODI/LODI/MAIN_files/Dabir2009.pdf |
| Alternate Webpage(s) | https://www.spiedigitallibrary.org/journalArticle/Download?fullDOI=10.1117/1.3103342 |
| Alternate Webpage(s) | https://www.spiedigitallibrary.org/journals/Journal-of-Biomedical-Optics/volume-14/issue-02/024030/Fully-automated-deconvolution-method-for-on-line-analysis-of-time/10.1117/1.3103342.pdf |
| Alternate Webpage(s) | https://biomedicaloptics.spiedigitallibrary.org/journalIssue/Download?DOI=10.1117/1.3103342&downloadType=journal+article&fullDOI=10.1117/1.3103342&isResultClick=True |
| Alternate Webpage(s) | https://www.spiedigitallibrary.org/journalArticle/Download?fullDOI=10.1117/1.3103342&isResultClick=False |
| Alternate Webpage(s) | https://doi.org/10.1117/1.3103342 |
| Journal | Journal of biomedical optics |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |