Please wait, while we are loading the content...
Please wait, while we are loading the content...
| Content Provider | World Health Organization (WHO)-Global Index Medicus |
|---|---|
| Author | Dahmani, Souhayl Paugam-Burtz, Catherine Gauss, Tobias Alves, Michael Le Bihan, Eric Necib, Scander Belghiti, Jacques Mantz, Jean |
| Description | Country affiliation: France Author Affiliation: Dahmani S ( Department of Anesthesia and Pain Medicine, Robert Debre University Hospital, Paris, France. souhayl.dahmani@rdb.aphp.fr) |
| Abstract | BACKGROUND AND OBJECTIVE: Liver transplantation is associated with important haemodynamic variations requiring cardiac output and oximetric data monitoring. The mixed venous saturation (SvO2) integrates parameters combining information about oxygen consumption, cardiac output and haemoglobin concentration. Central venous saturation (ScvO2) can be directly measured from blood drawn in the superior venous system via a central venous catheter. ScvO2 has been proposed as an alternative to SvO2 for intraoperative haemodynamic monitoring. The aim of the present study was to examine the level of agreement between SvO2 and ScvO2 during the preanhepatic and the neohepatic stage of liver transplantation in cirrhotic patients. MATERIALS AND METHODS: After agreement from the regulatory authorities for medical research and having obtained informed consent, 30 patients with cirrhosis undergoing liver transplantation were prospectively included. Blood gas samples were simultaneously drawn from the arterial line, the right atrium port and the pulmonary artery port of the catheter: during the preanhepatic stage (two times) and two times 30-40 min after graft revascularization. Arterial saturation (SaO2), haemoglobin concentration, cardiac index, SvO2, ScvO2 and oxygen consumption, delivery and extraction (VO2, DO2 and EO2, respectively) were measured. A Bland-Altman test was used to determine bias and limits of agreement between SvO2 and ScvO2. Both parameters were considered to be equivalent if limits of agreement were within +/-5%. RESULTS: Bland-Altman analysis revealed a bias (limit of agreement) of -1.2% (-9.1 to 6.6%), -0.3% (-4.8 to 4%) and -2.1% (-12 to 7.8%) for the overall measurements and preanhepatic and postgraft reperfusion measurements, respectively. SvO2 decreased significantly between hepatectomy and reperfusion, whereas cardiac index, VO2, DO2 and EO2 showed significantly higher values after reperfusion. ScvO2 and SaO2 levels did not display different values between the two periods. DISCUSSION: Measurements of SvO2 and ScvO2 showed a good level of agreement during the preanhepatic stage, whereas the level of agreement was low after liver graft reperfusion. The increase of VO2 associated with the decrease of SvO2 and the stability of ScvO2 between the two periods suggest an incomplete mixing of splanchnic venous blood into the right atrium. In addition, our samples were taken from the right atrium, which is not possible using a conventional central venous catheter, as the tip must lie in the superior vena cava and not in the right atrium. ScvO2 cannot be considered equivalent to SvO2 for the haemodynamic monitoring of patients with cirrhosis undergoing liver transplantation. |
| File Format | HTM / HTML |
| ISSN | 02650215 |
| Issue Number | 8 |
| Volume Number | 27 |
| e-ISSN | 13652346 |
| Journal | European Journal of Anaesthesiology |
| Language | English |
| Publisher | Lippincott Williams & Wilkins |
| Publisher Date | 2010-08-01 |
| Publisher Place | Great Britain (UK) |
| Access Restriction | One Nation One Subscription (ONOS) |
| Subject Keyword | Discipline Anesthesiology Catheterization, Central Venous Methods Liver Cirrhosis Surgery Liver Transplantation Monitoring, Intraoperative Oximetry Adult Blood Gas Analysis Standards Humans Metabolism Middle Aged Oxygen Consumption Physiology Pilot Projects Prospective Studies Comparative Study Journal Article |
| Content Type | Text |
| Resource Type | Article |
| Subject | Anesthesiology and Pain Medicine |
National Digital Library of India (NDLI) is a virtual repository of learning resources which is not just a repository with search/browse facilities but provides a host of services for the learner community. It is sponsored and mentored by Ministry of Education, Government of India, through its National Mission on Education through Information and Communication Technology (NMEICT). Filtered and federated searching is employed to facilitate focused searching so that learners can find the right resource with least effort and in minimum time. NDLI provides user group-specific services such as Examination Preparatory for School and College students and job aspirants. Services for Researchers and general learners are also provided. NDLI is designed to hold content of any language and provides interface support for 10 most widely used Indian languages. It is built to provide support for all academic levels including researchers and life-long learners, all disciplines, all popular forms of access devices and differently-abled learners. It is designed to enable people to learn and prepare from best practices from all over the world and to facilitate researchers to perform inter-linked exploration from multiple sources. It is developed, operated and maintained from Indian Institute of Technology Kharagpur.
Learn more about this project from here.
NDLI is a conglomeration of freely available or institutionally contributed or donated or publisher managed contents. Almost all these contents are hosted and accessed from respective sources. The responsibility for authenticity, relevance, completeness, accuracy, reliability and suitability of these contents rests with the respective organization and NDLI has no responsibility or liability for these. Every effort is made to keep the NDLI portal up and running smoothly unless there are some unavoidable technical issues.
Ministry of Education, through its National Mission on Education through Information and Communication Technology (NMEICT), has sponsored and funded the National Digital Library of India (NDLI) project.
| Sl. | Authority | Responsibilities | Communication Details |
|---|---|---|---|
| 1 | Ministry of Education (GoI), Department of Higher Education |
Sanctioning Authority | https://www.education.gov.in/ict-initiatives |
| 2 | Indian Institute of Technology Kharagpur | Host Institute of the Project: The host institute of the project is responsible for providing infrastructure support and hosting the project | https://www.iitkgp.ac.in |
| 3 | National Digital Library of India Office, Indian Institute of Technology Kharagpur | The administrative and infrastructural headquarters of the project | Dr. B. Sutradhar bsutra@ndl.gov.in |
| 4 | Project PI / Joint PI | Principal Investigator and Joint Principal Investigators of the project |
Dr. B. Sutradhar bsutra@ndl.gov.in Prof. Saswat Chakrabarti will be added soon |
| 5 | Website/Portal (Helpdesk) | Queries regarding NDLI and its services | support@ndl.gov.in |
| 6 | Contents and Copyright Issues | Queries related to content curation and copyright issues | content@ndl.gov.in |
| 7 | National Digital Library of India Club (NDLI Club) | Queries related to NDLI Club formation, support, user awareness program, seminar/symposium, collaboration, social media, promotion, and outreach | clubsupport@ndl.gov.in |
| 8 | Digital Preservation Centre (DPC) | Assistance with digitizing and archiving copyright-free printed books | dpc@ndl.gov.in |
| 9 | IDR Setup or Support | Queries related to establishment and support of Institutional Digital Repository (IDR) and IDR workshops | idr@ndl.gov.in |
|
Loading...
|