Clinical and radiological evaluation of revision hip arthroplasty using the cement-in-cement technique.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Goto, Koji Kawanabe, Keiichi Akiyama, Haruhiko Morimoto, Tadaoaki Nakamura, Toshitaka |
| Copyright Year | 2008 |
| Abstract | We reviewed 44 consecutive revision hip replacements in 38 patients performed using the cement-in-cement technique. All were performed for acetabular loosening in the presence of a well-fixed femoral component. The mean follow-up was 5.1 years (2 to 10.1). Radiological analysis at final follow-up indicated no loosening of the femoral component, except for one case with a continuous radiolucent line in all zones and peri-prosthetic fracture which required further revision. Peri-operative complications included nine proximal femoral fractures (20.4%) and perforation of the proximal femur in one hip. In five hips wiring or fixation with a braided suture was undertaken but no additional augmentation was required. There was an improvement in the mean Japanese Orthopaedic Association score from 55.5 (28 to 81) pre-operatively to 77.8 (40 to 95) at final follow-up (p < 0.001). Revision using a cement-in-cement technique allows increased exposure for acetabular revision and is effective in the medium term. Further follow-up is required to assess the long-term results in the light of in vitro studies which have questioned the quality of the cement-in-cement bond. |
| Starting Page | 9 |
| Ending Page | 14 |
| Page Count | 6 |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | http://www.bjj.boneandjoint.org.uk/content/jbjsbr/90-B/8/1013.full.pdf |
| PubMed reference number | 18669955v1 |
| Alternate Webpage(s) | https://doi.org/10.1302/0301-620X.90B8.20388 |
| DOI | 10.1302/0301-620x.90b8.20388 |
| Journal | The Journal of bone and joint surgery. British volume |
| Volume Number | 90 |
| Issue Number | 8 |
| Language | English |
| Access Restriction | Open |
| Subject Keyword | Femoral Fractures Follow-Up Report Fracture Hip Replacement Arthroplasty (procedure) Hip structure Medical Device Material Perforation Patients Renal Tubular Acidosis, Type II Revision procedure Surgical Replantation Surgical revision |
| Content Type | Text |
| Resource Type | Article |