Loading...
Please wait, while we are loading the content...
Similar Documents
Primary stability of bone-patellar tendon-bone graft fixation with biodegradable pins.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Weimann, Andre Zantop, Thore Rümmler, Markus Hassenpflug, Joachim Petersen, Wolf |
| Copyright Year | 2003 |
| Abstract | PURPOSE We evaluated the initial bone-patellar tendon-bone (BPTB) graft fixation strength of biodegradable pins compared with interference screws in anterior cruciate ligament reconstruction using bovine knees. TYPE OF STUDY Biomechanical in vitro study. METHODS Ten BPTB grafts from human donors fixed with 2 biodegradable 2.7-mm pins (Rigid Fix; Ethicon, Mitek Division, Norderstedt, Germany) crossing the bone block perpendicular and 10 BPTB grafts fixed with conventional biodegradable interference screws (Absolute Absorbable Interference Screw; Innovasive Devices, Marlborough, MA) underwent ultimate single-cycle failure loading at a rate of 200 mm/min. The grafts were fixed to bovine tibia to simulate young human femoral bone density. Failure mode, displacement before failure, and ultimate failure load were tested with a testing machine. The pullout force was in line with the bone tunnel to simulate a worst case scenario. RESULTS The failure mode for cross pins was either fracture of the bone block (5 specimens) or fracture of the articular pin (5 specimens). The failure mode for interference screws was slippage past the screw in all specimens. In the single cycle loading test, the mean yield load for the biodegradable pins was 400.2 (+/- 122.4) N, maximum load, 524.6 (+/- 136.6) N, with a mean stiffness of 155.2 (+/- 32.4) N/mm. The yield load at failure for the interference screw was 402.7 (+/- 143.9) N, maximum load 515.7 (+/- 168.5) N with a mean stiffness of 168 (+/- 42) N/mm. CONCLUSIONS Fixation of a BPTB graft with 2 biodegradable 2.7-mm pins (Rigid Fix) leads to primary stability that is comparable to fixation with biodegradable interference screws. |
| File Format | PDF HTM / HTML |
| DOI | 10.1016/j.arthro.2003.10.023 |
| Alternate Webpage(s) | http://prod.mitek.depuy.edgesuite.net/ResearchFilesforWebsite/Primary_Stability.pdf |
| PubMed reference number | 14673452 |
| Alternate Webpage(s) | https://doi.org/10.1016/j.arthro.2003.10.023 |
| Journal | Medline |
| Volume Number | 19 |
| Issue Number | 10 |
| Journal | Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |