Loading...
Please wait, while we are loading the content...
Similar Documents
A study of HVDC transmission line audible noise and corona loss in an indoor corona cage.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Lekganyane, Mokwape Johannah. |
| Copyright Year | 2007 |
| Abstract | The main objective of this research was to study DC conductor corona loss (CL) and audible noise (AN) in the context of local climatic conditions, through corona cage measurements, and do a comparative analysis of the measured data with results available in literature and EPRI TLW software simulation results. The ultimate aim was to assess the applicability of the software to our local conditions and hence determine, if necessary, appropriate correction factors for application in HYDC transmission line designs. For this study, short term measurements of corona AN and currents were carried out in an indoor meshed cylindrical corona cage, under DC and AC voltages. The cage was later converted into a short test line and some of the measurements repeated. The DC supply was obtained from a two stage ±500 kV Walton-Cockroft generator. The AC voltages were obtained from a 2x 100 kV, 50 Hz, AC test transformer set. The tests were performed using single solid and stranded aluminium conductors with three different diameters (1.6 cm, 2.8 cm, and 3.5 cm). All the measurements were carried out at low altitude. A CoroCAM I camera was used to determine the corona inception gradients and to observe the corona activity at different surface gradients and under different voltages and polarities. AN measurements at different conductor surface gradients were done using the Rohde&Schwarz and the Bruel&Kjaer sound level meters. To obtain the frequency spectra, a Bruel&Kjaer octave-band filter set attached to the sound level meter was used. The measured data was corrected for both height and length effects, and then compared with simulations from the EPRI-TLW software through curve fitting. A digital micro-ammeter connected to the centre of the cage through a 560 .Q measuring resistor was used to measure the corona current. Current pulses were viewed using a digital storage oscilloscope. To verifY the corona current results obtained from the cage measurements, current measurements were also done for a point-plane spark gap. The corona current data was, later on, used to evaluate the total corona power loss for DC. The results obtained from test line measurements were used to compare the CL and AN for different configurations. |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | http://researchspace.ukzn.ac.za/xmlui/bitstream/handle/10413/2193/Lekganyane_Mokwape_Johannah_2007.pdf?isAllowed=y&sequence=1 |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |