Loading...
Please wait, while we are loading the content...
Similar Documents
Revision cochlear implantation following internal auditory canal insertion.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Heman-Ackah, Selena E. Friedmann, David R. Cosetti, Maura K. Waltzman, Susan B. Roland, J. Thomas |
| Copyright Year | 2013 |
| Abstract | OBJECTIVES/HYPOTHESIS In pediatric patients with congenital malformations of the inner ear, anomalies within the anatomy may facilitate unintentional insertion of the cochlear implant electrode into the internal auditory canal. Revision procedures for removal and replacement of cochlear implant electrodes following internal auditory canal insertion are fraught with potential danger, including the theoretical risk of injury to vasculature within the internal auditory canal, repeat insertion within the internal auditory canal, and cerebrospinal fluid leak. The objective of this presentation is to describe a technique for revision cochlear implantation following internal auditory canal insertion to minimize the potential associated risks. STUDY DESIGN Case series. METHODS A retrospective chart review was performed on all patients at a tertiary care facility who underwent revision cochlear implantation for internal auditory canal insertion between January 1999 and July 2011. RESULTS A total of four patients referred from outside institutions have undergone revision cochlear implantation for internal auditory canal insertion. The records from these patients were reviewed. Electrodes were safely removed in all cases without injury to the anterior inferior cerebellar artery or its branches (i.e., labyrinthine artery). Complete insertion was accomplished on reimplantation. Neural response telemetry was performed in all cases, and responses were noted. Fluoroscopy was utilized to visualize electrode progression during insertion. A detailed description of the operative technique is provided. CONCLUSIONS This case series describes a technique for revision cochlear implantation that appears to be safe and effective in preventing potential associated complications. |
| Starting Page | 39 |
| Ending Page | 42 |
| Page Count | 4 |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | http://www.sbccp.org.br/arquivos/LG2013-12/lary23340.pdf |
| PubMed reference number | 24114888v1 |
| Alternate Webpage(s) | https://doi.org/10.1002/lary.23340 |
| DOI | 10.1002/lary.23340 |
| Journal | The Laryngoscope |
| Volume Number | 123 |
| Issue Number | 12 |
| Language | English |
| Access Restriction | Open |
| Subject Keyword | Anatomic structures Blood supply aspects Cavernous Hemangioma of Brain Cerebrospinal fluid leak Chart evaluation by healthcare professional Clinical act of insertion Cochlear Implants Cochlear implant procedure Cochlear nucleus structure Cochlear structure Congenital Abnormality Dental caries External auditory canal structure Hearing problem Insertion Mutation Internal acoustic meatus of temporal bone Labyrinth Patients Removal of implant (procedure) Revision procedure Structure of anterior inferior cerebellar artery Structure of cerebellar artery Structure of labyrinthine artery Surgical Replantation Surgical revision Telemetry Tertiary Healthcare X-Linked Combined Immunodeficiency Diseases electrode |
| Content Type | Text |
| Resource Type | Article |