Loading...
Please wait, while we are loading the content...
Materials and methods for higher performance screen-printed flexible MRI receive coils.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Corea, Joseph Russell LechĂȘne, Pierre Balthazar Lustig, Michael Arias, Ana Claudia |
| Copyright Year | 2017 |
| Abstract | PURPOSE To develop methods for characterizing materials used in screen-printed MRI coils and improve signal-to-noise ratio (SNR) with new lower-loss materials. METHODS An experimental apparatus was created to characterize dielectric properties of plastic substrates used in receive coils. Coils were fabricated by screen printing conductive ink onto several plastic substrates. Unloaded and sample loaded quality factor (QUnloaded /QLoaded ) measurements and scans on a 3T scanner were used to characterize coil performance. An experimental method was developed to describe the relationship between a coil's QUnloaded and the SNR it provides in images of a phantom. In addition, 3T scans of a phantom and the head of a volunteer were obtained with a proof-of-concept printed eight-channel array, and the results were compared with a commercial 12-channel array. RESULTS Printed coils with optimized substrates exhibited up to 97% of the image SNR when compared with a traditional coil on a loading phantom. QUnloaded and the SNR of coils were successfully correlated. The printed array resulted in images comparable to the quality given by the commercial array. CONCLUSION Using the proposed methods and materials, the SNR of printed coils approached that of commercial coils while using a new fabrication technique that provided more flexibility and close contact with the patient's body. Magn Reson Med 78:775-783, 2017. © 2016 International Society for Magnetic Resonance in Medicine. |
| Starting Page | 775 |
| Ending Page | 783 |
| Page Count | 9 |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | https://www.ocf.berkeley.edu/~arias/public/publications/files/corea2016materials.pdf |
| PubMed reference number | 27612330v1 |
| Alternate Webpage(s) | https://doi.org/10.1002/mrm.26399 |
| DOI | 10.1002/mrm.26399 |
| Journal | Magnetic resonance in medicine |
| Volume Number | 78 |
| Issue Number | 2 |
| Language | English |
| Access Restriction | Open |
| Subject Keyword | Coil Device Component Ink (substance) Patients Phantoms, Imaging Relative Biological Effectiveness Scanner Device Component Signal-To-Noise Ratio |
| Content Type | Text |
| Resource Type | Article |