A γ detector movement system of the spectrometer with a vertex detector setup
| Content Provider | Semantic Scholar |
|---|---|
| Author | Golovkin, Valery Golovnya, S. N. Gorokhov, S. Ustinov, Eugene |
| Copyright Year | 2014 |
| Abstract | The system controlling movement of the γ detector in the spectrometer with a vertex detector (SVD) setup has been upgraded. The choice of circuitry components for designing the control interface, coordinate sensors, actuation mechanisms, and system of emergency shutdown is substantiated. The circuit designs allowing the reliability of the γ detector and its positioning accuracy to be increased are described. Commercially produced industrial controllers of asynchronous motors with frequency steering are used in the system. The software developed for controlling the γ detector movement is described. The system has been completely mounted and tested and now is ready for operation as a part of the SVD setup. |
| Starting Page | 274 |
| Ending Page | 278 |
| Page Count | 5 |
| File Format | PDF HTM / HTML |
| DOI | 10.1134/S0020441214020067 |
| Volume Number | 57 |
| Alternate Webpage(s) | https://page-one.springer.com/pdf/preview/10.1134/S0020441214020067 |
| Alternate Webpage(s) | https://doi.org/10.1134/S0020441214020067 |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |