Loading...
Please wait, while we are loading the content...
Similar Documents
Calibration of the RPC charge readout in the ARGO-YBJ experiment
| Content Provider | Semantic Scholar |
|---|---|
| Author | Aielli, Giulio Bacci, Cesare Bartoli, B. Bernardini, P. Bleve, Cosimo Branchini, Paolo Budano, A. Bussino, Severino Angelo Maria Melcarne, A. K. Calabrese Camarri, Paolo Cao, Zihuang Cappa, Álvaro Cardarelli, Roberto Catalanotti, S. Cattaneo, Claudio Celio, Paola Chen, S. Z. Chen, T. L. Chen, Y. B. Cheng, Ning Cretì, Patrizia Staiti, G. D'Al'i Danzengluobu Dattoli, M. Mitri, Ivan De Piazzoli, Benedetto D'Ettorre Vincenzi, Mario De Girolamo, Tristano Di Ding, X. H. Sciascio, Giuseppe Di Feng, Cunfeng Feng, Zhaoyang Feng, Zhenyong Galeazzi, Filippo Galeotti, Piero Gargana, Riccardo He, Huihai Hu, Haibing Hu, Hongbo Huang, Qing Iacovacci, Michele Iuppa, Roberto James, Irina Jia, Huanyu Labaciren Li, Jiangyu Li, Xing Xiao Liberti, Barbara Liguori, G. Liu, Chaoqiang Liu, Ming Lu, Honglin Ma, Xinhua Mancarella, G. Mari, Stefano Maria Marsella, Giovanni Martello, Daniele Mastroianni, Stefano Meng, X. R. Montini, Paolo Ning, C. C. Pagliaro, Andrea Panareo, Marco Perrone, Leonardo Pistilli, P. Rossi, Elio Ruggieri, Federico Saggese, L. Salvini, Pietro Santonico, Rinaldo Shen, P. R. Sheng, Xiangdong Shi, Feng Stanescu, Cristian Surdo, Anthonoy Lo Vallania, Piero Vernetto, Silvia Vigorito, Carlo Wang, Baolin Wang, H. W. Xu, Bingwei Xue, Lei-Ping Yang, Q. Y. Yang, X. C. Yuan, A. F. Zhang, H. Michael Zhang, Jian-Hui Zhang, Jianli Zhang, Lufeng Zhang, Panxing Zhang, Xin Yue Zhang, Yu Zhaxisangzhu Zhou, Xinyue Zhu, Fu Rong Zizzi, Giovanni |
| Copyright Year | 2012 |
| Abstract | Abstract The charge readout of Resistive Plate Chambers (RPCs) is implemented in the ARGO-YBJ experiment to measure the charged particle density of the shower front up to 10 4 /m 2 , enabling the study of the primary cosmic rays with energies in the “knee” region. As the first time for RPCs being used this way, a telescope with RPCs and scintillation detectors is setup to calibrate the number of charged particles hitting a RPC versus its charge readout. Air shower particles are taken as the calibration beam. The telescope was tested at sea level and then moved to the ARGO-YBJ site for coincident operation with the ARGO-YBJ experiment. The charge readout shows good linearity with the particle density in the dynamic range (up to 200/m 2 ). |
| Starting Page | 56 |
| Ending Page | 59 |
| Page Count | 4 |
| File Format | PDF HTM / HTML |
| DOI | 10.1016/j.nima.2010.09.066 |
| Volume Number | 661 |
| Alternate Webpage(s) | http://argo.na.infn.it/argoart/Collab_art/NIM_A-RPC.pdf |
| Alternate Webpage(s) | http://argo.na.infn.it/argoart/Collab_art/NIM_A661_2012_556-ChargeCalibration.pdf |
| Alternate Webpage(s) | http://argo.na.infn.it/argoart/Collab_art/NIM_A783_2015_68-CalibAnalog.pdf |
| Alternate Webpage(s) | https://galprop.stanford.edu/elibrary/icrc/2009/preliminary/pdf/icrc0796.pdf |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |