Loading...
Please wait, while we are loading the content...
Similar Documents
Sensitivity and Specificity of a Novel Approach to Confirm the Depth of the Endotracheal Tube
| Content Provider | Semantic Scholar |
|---|---|
| Author | Li, Yansong Xie, Ying Hu, Bailong Wang, Jing Song, Haibo Wei, Xinchuan Kazuo, Hanaoka. |
| Copyright Year | 2015 |
| Abstract | This study aimed to explore the sensitivity and specificity an approach to confirm the depth of the endotracheal tube. It was a prospective, diagnostic study (Registration number: chiCTR-TRC-14005170) conducted in the Department of Anesthesiology of West China Hospital. A total of 100 patients underwent general anesthesia were included. The distance between the upper margin of the cuff and the manubriosternal joint (CM) and the distance between the upper margin of the cuff and the carina (CC) were measured. The accuracy of the confirmed approach against fiberoptic bronchoscopy (FOB) was evaluated. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated. The correlation and agreement between CM and CC were explored.The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were determined to be 94.74% (95% CI: 87.07-98.55%), 79.17% (95% CI: 57.85-92.87%), 93.51% (95% CI: 85.49-97.86%), 82.61% (95% CI: 61.22%-95.05%), respectively. The κ value was 0.75 (95% CI: 0.60-0.90). There was a significant correlation between CM and CC (P < 0.001) with a correlation coefficient of 0.91(95% CI: 0.87-0.94). Bland and Altman plots also demonstrated a good agreement between the CM and CC. This novel method may be used to confirm the depth of the endotracheal tubes. |
| Starting Page | 459 |
| Ending Page | 462 |
| Page Count | 4 |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/56/eb/medi-94-e1460.PMC4602919.pdf |
| PubMed reference number | 4602919 |
| Alternate Webpage(s) | https://doi.org/10.1097/MD.0000000000001460 |
| DOI | 10.1097/md.0000000000001460 |
| Journal | Medicine |
| Volume Number | 94 |
| Language | English |
| Access Restriction | Open |
| Subject Keyword | Cardiomyopathies Coefficient Fiberoptic Device Component Fiberoptic bronchoscopy Negative Predictive Value of Diagnostic Test Nucleopolyhedrovirus Patients Positive Predictive Value of Diagnostic Test Specimen Source Codes - Tube Structure of carina |
| Content Type | Text |
| Resource Type | Article |