| Abstract | BACKGROUND Radiofrequency catheter ablation (RCA) of supraventricular tachycardia (SVT) in children is highly successful but requires exposure to radiation. Nonfluoroscopic mapping systems may significantly reduce fluoroscopy time. METHODS Forty consecutive pediatric patients who underwent RCA for accessory pathways (AP) or AV nodal reentrant tachycardia (AVNRT) with use of a nonfluoroscopic navigation system (Ensite NavX) (group A) were compared retrospectively to 40 consecutive patients with similar diagnoses who underwent RCA with fluoroscopic guidance only (group B). RESULTS Group A (mean age 12.1+/-2.9 years, mean weight 47+/-13.9 kg) consisted of 11 patients (27.7%) with AVNRT and 29 (72.5%) with AP. Group B (mean age 10.9+/-3.1 years, mean weight 47.1+/-17.1 kg) consisted of 7 patients (17.5%) with AVNRT and 33 (82.5%) with AP. There were no significant differences in AP location, patients with congenital heart disease, and number of radiofrequency lesions. Fluoroscopy time was significantly shorter in group A than in group B (10.4+/-6.1, range 3.1-28.8 minutes, vs 24.9+/-16.0, range 4.4-82.0 minutes, P<0.0001). Procedure duration was also significantly shorter in group A than in group B (170+/-68.5, range 90-420 minutes, vs 218+/-69.3, range 90-360 minutes, P<0.0001). Initial success was 95% in group A and 100% in group B. Tachycardia recurrences occurred in two patients in group A (5%) and six patients in group B (15%). Final success, including repeat ablations for recurrences or failures, was 100% in both groups. CONCLUSIONS The use of a nonfluoroscopic system for catheter navigation significantly reduced fluoroscopy exposure and total procedure duration of RCA of common SVT substrates in children. |
| Starting Page | 36 |
| Ending Page | 41 |
| Page Count | 6 |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | https://pdf.xuebalib.com/xuebalib.com.18023.pdf |
| Alternate Webpage(s) | http://download.xuebalib.com/xuebalib.com.18023.pdf |
| PubMed reference number | 16981921v1 |
| Volume Number | 29 |
| Issue Number | 9 |
| Journal | Pacing and clinical electrophysiology : PACE |
| Language | English |
| Access Restriction | Open |
| Subject Keyword | Accessory Atrioventricular Bundle (disorder) Cardiac ablation Catheter Ablation, Radiofrequency Congenital heart disease Destructive procedure (surgical) Heart Diseases Patients Recurrence (disease attribute) Supraventricular tachycardia Tachycardia, Atrioventricular Nodal Reentry Tachycardia, Ventricular radiofrequency ablation |
| Content Type | Text |
| Resource Type | Article |