Refractive Outcomes of Posterior Chamber Phakic Intraocular Lens Implantation for Correction of Myopia and Myopic Astigmatism
| Content Provider | Semantic Scholar |
|---|---|
| Author | Pjano, Melisa Ahmedbegovic Pidro, Ajla Biscevic, Alma Grišević, Senad Pandzic, Bojana Cerović, Vesna |
| Copyright Year | 2017 |
| Abstract | OBJECTIVES The aim was to examine efficacy and safety after Implantable Collamer Lens (ICL) implantation for correction of myopia et myopic astigmatism. METHODS This prospective clinical study included 28 eyes of 16 patients which underwent implantation of ICL for correction of myopia up to -18,00 diopters (D) and myopic astigmatism up to -6,00 D in the Eye Clinic Svjetlost Sarajevo, from January 2013 to January 2016. Uncorrected distance visual acuity (UDVA), spherical equivalent (SE), corrected distance visual acuity (CDVA), intraocular pressure (IOP), endothelial cell (EC) density were evaluated at one, six and twelve months. For statistical analysis SPSS for Windows and Microsoft Excel were used. RESULTS Out of 16 patients, with mean age of 28,21 ± 4,06 years, 12 of them had binocular and 4 of them had monocular procedure. After 12 months mean UDVA was 0,76 ± 0,16 compared to UDVA 0,04 ± 0,03 preoperatively. Mean SE preoperatively was -0,21 ± 0,27 D compared to -9,52 ± 3,69 D preoperatively. At 12 months one eye (3,57%) lost 2 Snellen lines. In this study 8 eyes (28,57%) gained 1 line, 5 eyes gained (17,56%) 2 lines, and 3 eyes (10,72%) gained 3 lines. EC loss was 5,50±4.71% after 12 months. There was no significant change of IOP by the end of 12 months follow up period. One haptic crack was reported as the only intraoperative complication. Three postoperative complications were: two lens rotations and one retinal detachment. CONCLUSION Implantation of ICL is an effective and safe method for reducing or correcting myopia and myopic astigmatism. |
| Starting Page | 93 |
| Ending Page | 96 |
| Page Count | 4 |
| File Format | PDF HTM / HTML |
| PubMed reference number | 28790537v1 |
| Alternate Webpage(s) | https://doi.org/10.5455/medarh.2017.71.93-96 |
| DOI | 10.5455/medarh.2017.71.93-96 |
| Journal | Medical archives |
| Volume Number | 71 |
| Language | English |
| Access Restriction | Open |
| Subject Keyword | Astigmatism Bimalleolar Fractures Endothelial Cells Eye Gain Haptic Device Component Intraoperative Complications Lens Diseases Myopia Optic Nerve Glioma, Childhood Patients Physiologic Intraocular Pressure Retina Retinal Detachment diopters hearing impairment |