Prospective assessment of the Hong Kong Hospital Authority universal Down syndrome screening programme.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Sahota, Daljit Singh Leung, Wing Cheong Chan, Wan Pang To, William Lau, Elizabeth Tak Kwong Leung, T. Y. |
| Copyright Year | 2013 |
| Abstract | OBJECTIVE To evaluate the performance of the locally developed universal Down syndrome screening programme. DESIGN Population-based cohort study in the period July 2010 to June 2011 inclusive. SETTING Four Hong Kong Hospital Authority Departments of Obstetrics and Gynaecology and a central university-based laboratory for maternal serum processing and risk determination. PARTICIPANTS Women were offered either a first-trimester combined test (nuchal translucency, free beta human chorionic gonadotropin, and pregnancy-associated plasma protein-A) or nuchal-translucency-only test, or a second-trimester double test (alpha-fetoprotein and total human chorionic gonadotropin) for detection of Down syndrome according to their gestational age. Those with a trisomy 21 term risk of 1:250 or higher were offered a diagnostic test. RESULTS A total of 16 205 pregnancies were screened of which 13 331 (82.3%) had a first-trimester combined test, 125 (0.8%) had a nuchal-translucency test only, and 2749 (17.0%) had a second-trimester double test. There were 38 pregnancies affected by Down syndrome. The first-trimester screening tests had a 91.2% (31/34) detection rate with a screen-positive rate of 5.1% (690/13 456). The second-trimester test had a 100% (4/4) detection rate with a screen-positive rate of 6.3% (172/2749). There were seven (0.9%) pregnancies that miscarried following an invasive diagnostic test. There were two Down syndrome-affected live births, both with an estimated first-trimester trisomy 21 term risk lower than 1:250. CONCLUSION The universal screening programme offered at the four units was effective and achieved the expected detection rates and low false-positive rates, and to maintain these, the current emphasis on training, quality control, and regular auditing must continue. |
| File Format | PDF HTM / HTML |
| PubMed reference number | 23535668 |
| Journal | Medline |
| Volume Number | 19 |
| Issue Number | 2 |
| Alternate Webpage(s) | http://www.hkmj.org/system/files/hkm1304p101.pdf |
| Journal | Hong Kong medical journal = Xianggang yi xue za zhi |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |