Optimization and Response Surface Modeling of Chromium Removal Zero Valent Iron ( NZVI )
| Content Provider | Semantic Scholar |
|---|---|
| Author | Gholinezhad, Mehrtash Ramzanpour, Mahmoud Reza Zamani, A. Asgari |
| Copyright Year | 2016 |
| Abstract | The ability use of NZVI for the Heavy Metal such as Chromium from aqueous solution has been investigated in batch mode examinations. Amount removal of Chromium is found to be 98.87% at pH: amount of adsorbent dosage of 0.01 g in 20 minutes and 5 ppm Chromium solution. Influences of parameters like initial Chromium concentration (5-15 mg/L), time (20 NZVI dosage (0.005-0.02 g) on Chromium adsorption were examinated using response surface methodology. The Box Behnken experimental design in response surface methodology was used for designing the experiments were run as well as for full response surface estimation and 15 trials as per the model. The optimum conditions for maximum removal of Chromium from an aqueous solution of 10 mg/L were as follows: adsorbent dosage (0 20 minutes initial Chromium concentration (5 ppm) in pH: 4. The high correlation coefficient (R2:0.971) between the model and the experimental data showed that the Box Behnken experimental design was able to predict the removal of Chromium using NZVI from aqueous solution effectually. |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | https://ijair.org/administrator/components/com_jresearch/files/publications/IJAIR_537_Final.pdf |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |