Loading...
Please wait, while we are loading the content...
Similar Documents
Slant Column Measurements of O3 and NO2 During the NDSC Intercomparison of Zenith-Sky UV-Visible Spectrometers in June 1996
| Content Provider | Semantic Scholar |
|---|---|
| Author | Roscoe, Howard K. Johnston, Peter V. Roozendael, M. Van Richter, Achim Sarkissian, Alain Roscoe, J. Preston, Kerry E. Lambert, J-C. Hermans, Christian DeCuyper, W. Dzienus, S. Winterrath, Tanja Burrows, J. P. Goutail, Florence Pommereau, J-P. D'Almeida, E. A. Hottier, J. Coureul, C. Didier, Roux Pundt, Irène Bartlett, Lyle M. McElroy, Charles Thomas Kerr, J. E. Elokhov, Aleksandr S. Giovanelli, Giorgio Ravegnani, Fabrizio Premuda, Margherita Kostadinov, Iv. Erle, F. Wagner, Tanita Da Silva Pfeilsticker, Klaus Kenntner, Martin Marquard, Lena Puentedura, Olga Yela, Margarita Arlander, D. W. Hoiskar, B. A. Kastad Tellefsen, Cathrine Wahlstrøm Tornkvist, K. Karlsen Heese, B. Jones, R. L. Aliwell, Simon Freshwater, Raymond A. |
| Copyright Year | 1999 |
| Abstract | In June 1996, 16 UV-visible sensors from 11 institutes measured spectra of the zenith sky for more than 10 days. Spectra were analysed in real-time to determine slant column amounts of O3 and NO2. Spectra of Hg lamps and lasers were measured, and the amount of NO2 in a cell was determined by each spectrometer. Some spectra were re-analysed after obvious errors were found. Slant columns were compared in two ways: by examining regression analyses against comparison instruments over the whole range of solar zenith angles; and by taking fractional differences from a comparison instrument at solar zenith angles between 85° and 91°. Regression identified which pairs of instruments were most consistent, and so which could be used as universal comparison instruments. For O3, regression slopes for the whole campaign agreed within 5% for most instruments despite the use of different cross-sections and wavelength intervals, whereas similar agreement was only achieved for NO2 when the same cross-sections and wavelength intervals were used and only one half-day's data was analysed. Mean fractional differences in NO2 from a comparison instrument fall within ±7% (1-sigma) for most instruments, with standard deviations of the mean differences averaging 4.5%. Mean differences in O3 fall within ±2.5% (1- sigma) for most instruments, with standard deviations of the mean differences averaging 2%. Measurements of NO2 in the cell had similar agreement to measurements of NO2 in the atmosphere, but for some instruments measurements with cell and atmosphere relative to a comparison instrument disagreed by more than the error bars. |
| Starting Page | 281 |
| Ending Page | 314 |
| Page Count | 34 |
| File Format | PDF HTM / HTML |
| DOI | 10.1023/A:1006111216966 |
| Volume Number | 32 |
| Alternate Webpage(s) | http://iup.physik.uni-bremen.de/doas/paper/jac_99_roscoe.pdf |
| Alternate Webpage(s) | https://doi.org/10.1023/A%3A1006111216966 |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |