Loading...
Please wait, while we are loading the content...
Phosphate removal with several thrice-weekly dialysis methods in overweight hemodialysis patients.
| Content Provider | Semantic Scholar |
|---|---|
| Author | Tonelli, Marcello Wang, Wenjie Hemmelgarn, Brenda R. Lloyd, Anita M. Manns, Braden J. |
| Copyright Year | 2009 |
| Abstract | BACKGROUND Currently available phosphate binders are associated with either hypercalcemia or high costs, which limit their use in hemodialysis patients. Whether modifying dialysis prescription to intensify small-solute clearance also leads to better phosphate clearance is unknown. STUDY DESIGN Randomized crossover trial. PARTICIPANTS Large patients (>80 kg; N = 18) who could not achieve adequate Kt/V during a standard 4-hour thrice-weekly prescription of maintenance hemodialysis. INTERVENTION 2 high-flux dialyzers in parallel for 4 hours in comparison to 3 other dialysis modalities (4 hours of standard hemodialysis, 4.5 hours of hemodialysis, and 4 hours of hemodialysis with increased dialysate flow). OUTCOMES (1) Predialysis serum phosphate level, (2) postdialysis phosphate level, (3) phosphate clearance, and (4) phosphate removal, all assessed during the last midweek session for each of the 4 different modalities. RESULTS Mean baseline predialysis serum phosphate level was 5.95 +/- 1.95 mg/dL. Using 2 dialyzers in parallel was associated with a significant decrease in predialysis serum phosphate level compared with standard hemodialysis (1.33 mg/dL lower; P = 0.01). Mean serum postdialysis serum phosphate levels during the last treatment of the double-dialyzer period were also lower by 0.43 and 0.74 mg/dL than during the last treatment of the standard-hemodialysis (P = 0.05) and increased-dialysate-flow (P < 0.001) periods, respectively. The double-dialyzer strategy also was associated with greater phosphate clearance (177.2 [corrected] mL/min; 95% confidence interval [CI], 158.6 to 195.9) [corrected] than the other 3 strategies (129.8 [corrected] mL/min; 95% CI, 111.2 to 148.4; 135.4 mL/min; 95% CI, 115.4 to 155.3; and 131.2 mL/min; 95% CI, 112.0 to 150.4), [corrected] but not greater phosphate removal. LIMITATIONS Small sample size, short study duration, and results of phosphate removal analysis inconclusive. CONCLUSION Use of 2 dialyzers in parallel for 6 weeks in overweight hemodialysis patients led to substantially lower predialysis phosphate levels. Future studies should explore the potential contribution of increased dialyzer surface area to better control of serum phosphate levels in maintenance hemodialysis patients. |
| File Format | PDF HTM / HTML |
| DOI | 10.1053/j.ajkd.2009.05.018 |
| PubMed reference number | 19619920 |
| Journal | Medline |
| Volume Number | 54 |
| Issue Number | 6 |
| Alternate Webpage(s) | https://vincentbourquin.files.wordpress.com/2010/03/s0272638609008634.pdf |
| Alternate Webpage(s) | https://doi.org/10.1053/j.ajkd.2009.05.018 |
| Journal | American journal of kidney diseases : the official journal of the National Kidney Foundation |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |