Loading...
Please wait, while we are loading the content...
Similar Documents
Comparación De Las Técnicas De Detección De Cruce Por Cero Y La Transformada Z-chirp Para Medir Frecuencias En El Rango Ultrasónico
| Content Provider | Semantic Scholar |
|---|---|
| Author | Cerda, Guadalupe Aguilar Velázquez, Luis Morales |
| Copyright Year | 2018 |
| Abstract | Resumen Este trabajo presenta una comparativa entre 2 metodos para detectar y medir la frecuencia con una alta precision en el rango ultrasonico. La aplicacion propuesta para esta investigacion es la medicion de velocidad con ultrasonido mediante efecto el Doppler en actuadores lineales, esta se desarrollara en un trabajo posterior. Se generaron senales sinteticas con distintos niveles de ruido, simulando la senal entregada por un sensor ultrasonico. Para la deteccion de frecuencia se diseno una metodologia para comparar las tecnicas de deteccion de cruce por cero y la Transformada-Z Chirp. La Transformada-Z Chirp, tiene mejores resultados ya que se tiene una buena aproximacion de la frecuencia real, y el error no incrementa en senales con ruido, en cambio en la deteccion de cruce por cero el error incrementa mostrando unos picos indeseables. Una vez que la metodologia se perfeccione, se implementara en un sistema embebido para el procesamiento en tiempo real. Palabras Claves: Alta resolucion, deteccion de cruce por cero, efecto Doppler, estimacion de frecuencia, transformada-Z Chirp, ultrasonido. COMPARISON BETWEEN ZERO-CROSSING DETECTION AND Z-CHIRP TRANSFORMED TECHNIQUES TO MEASURE FREQUENCIES IN THE ULTRASONIC RANGE Abstract This work presents a comparison between 2 methods to detect and measure the frequency with a high precision in the ultrasonic range. The proposed application for this research is the measurement of velocity with ultrasound by Doppler effect in linear actuators, this will be developed in a later work. Synthetic signals were generated with different levels of noise, simulating the signal delivered by an ultrasonic sensor. For frequency detection, a methodology was designed to compare zero crossing detection techniques and the Chirp Z-Transform. The Chirp Z-Transform, has better results since it has a good approximation of the real frequency, and the error does not increase in signals with noise, instead in the detection of crossing by zero the error increases showing some undesirable peaks. Once the methodology is perfected, it will be implemented in an embedded system for real-time processing. Keywords : Chirp z-transform, Doppler effect, frequency estimation, high resolution, ultrasound, zero crossing detection. |
| File Format | PDF HTM / HTML |
| Volume Number | 39 |
| Alternate Webpage(s) | http://www.itcelaya.edu.mx/ojs/index.php/pistas/article/download/1160/933 |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |