Loading...
Please wait, while we are loading the content...
Similar Documents
A Slug Test for Determining Hydraulic Conductivity of Unconfined Aquifers With Completely or Partially Penetrating Wells
| Content Provider | Semantic Scholar |
|---|---|
| Author | Bouwer, Herman Rice, Robert C. |
| Copyright Year | 1976 |
| Abstract | ~. help ed. steady Proc. With the slug test the hydraulic conductivity or transmissibility of an aquifer is determined from the rate of rise of the water level in a well after a certain volume or 'slug' of water is suddenly removed from the welL. The slug test is simpler and quicker than the Theis pumping test because observation wells and pumping the well are not needed. With the slug test the portion of the aquifer 'sampled' for hydraulic conductivity is smaller than that for the pumping test even though with the latter, most of the head loss also occurs within a relatively small distance of the pumped well and the resulting transmissibility primarily reflects the aquifer conditions near the pumped welL. Essentially instantaneous lowering of the water level in a well can be achieved by quickly removing water with a bailer or by partially or completely submerging an object in the water, letting the water level reach equilibrium, and then quickly removing the object. If the aquifer is very permeable, the water level in the well may rise very rapidly. Such rapid rises can be measured with sensitive pressure transducers and fast-response strip chart recorders or x-y plotters. Also it may be possible to isolate portions of the perforated or screened section of the well with special packers for the slug test. This not only reduces the inflow and hence the rate of rise of the water level in the well, but it also makes it possible to determine the vertical distribution of the hydraulic conductivity. Special packer techniques may have to be developed to obtain a good seal, especially for rough casings or perforations. Effective sealing may be achieved with relatively long sections of inflatable stoppers or tubing. The use of long sections of these materials would also reduce leakage flow from the rest of the well to the isolated section between packers. This flow can occur through gravel envelopes or other permeable zones surrounding the casing. Sections of inflatable tubing may have to be long enough to block off the entire part of the well not used for the slug test. High inflation pressures should be used to minimize volume changes in the tubing due to changing water pressures in the isolated section when the head is lowered. So far, solutions for the slug test have been developed only for completely penetrating wells in confined aquifers. Cooper et at. (1967) derived an equation for the rise or fall of the water level in a well after sudden lowering or raising, respectively. Their equation was based on nonsteady flow to a pumped, |
| Starting Page | 423 |
| Ending Page | 428 |
| Page Count | 6 |
| File Format | PDF HTM / HTML |
| DOI | 10.1029/WR012i003p00423 |
| Volume Number | 12 |
| Alternate Webpage(s) | http://www.cof.orst.edu/cof/fe/watershd/fe538/Watershed_10_HillslopeModule/Bouwer_Rice_slug_test_hydraulic_conductivity_WRR1976.pdf |
| Alternate Webpage(s) | https://doi.org/10.1029/WR012i003p00423 |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |