Loading...
Please wait, while we are loading the content...
Similar Documents
Comparison of the AdvanSure Human Papillomavirus Screening Real-Time PCR, the Abbott RealTime High Risk Human Papillomavirus Test, and the Hybrid Capture Human Papillomavirus DNA Test for the Detection of Human Papillomavirus
| Content Provider | Semantic Scholar |
|---|---|
| Author | Hwang, Yusun Lee, Miae |
| Copyright Year | 2012 |
| Abstract | BACKGROUND We evaluated the performance of various commercial assays for the molecular detection of human papillomavirus (HPV); the recently developed AdvanSure HPV Screening real-time PCR assay (AdvanSure PCR) and the Abbott RealTime High Risk HPV PCR assay (Abbott PCR) were compared with the Hybrid Capture 2 HPV DNA Test (HC2). METHODS All 3 tests were performed on 177 samples, and any sample that showed a discrepancy in any of the 3 tests was genotyped using INNO-LiPA HPV genotyping and/or sequencing. On the basis of these results, we obtained a consensus HPV result, and the performance of each test was evaluated. We also evaluated high-risk HPV 16/18 detection by using the 2 real-time PCR assays. RESULTS Among the 177 samples, 65 were negative and 75 were positive in all 3 assays; however, the results of the 3 assays with 37 samples were discrepant. Compared with the consensus HPV result, the sensitivities and specificities of HC2, AdvanSure PCR, and Abbott PCR were 97.6%, 91.7%, and 86.9% and 83.9%, 98.8%, and 100.0%, respectively. For HPV type 16/18 detection, the concordance rate between the AdvanSure PCR and Abbott PCR assays was 98.3%; however, 3 samples were discrepant (positive in AdvanSure PCR and negative in Abbott PCR) and were confirmed as HPV type 16 by INNO-LiPA genotyping and/or sequencing. CONCLUSIONS For HPV detection, the AdvanSure HPV Screening real-time PCR assay and the Abbott PCR assay are less sensitive but more specific than the HC2 assay, but can simultaneously differentiate type 16/18 HPV from other types. |
| Starting Page | 201 |
| Ending Page | 205 |
| Page Count | 5 |
| File Format | PDF HTM / HTML |
| DOI | 10.3343/alm.2012.32.3.201 |
| PubMed reference number | 22563555 |
| Journal | Medline |
| Volume Number | 32 |
| Alternate Webpage(s) | https://synapse.koreamed.org/Synapse/Data/PDFData/3039ALM/alm-32-201.pdf |
| Alternate Webpage(s) | https://doi.org/10.3343/alm.2012.32.3.201 |
| Journal | Annals of laboratory medicine |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |