| Abstract | The purpose of this study is to estimate radiation dose and image quality of ECG-gated coronary 320-area detector CT (ADCT) angiography which was acquired using the protocols that were considered as optimal methods for different heart rates (HR) in 1031 consecutive patients (M/F=580/451, 65 ± 12 yr) without arrhythmias. We set up 5 protocols for 320-ADCT based on the relationship among heart rates, temporal resolution, gantry rotation speed, optimal reconstruction phase and slow filling phase on 64-multidetector-row computed tomography (MDCT), ie, 1) mid-diastolic (75% of RR) 1 beat scan (MD 1 beat, N=761(73.8%)) for HR ≤ 60, 2) mid-diastolic (75% of RR) 2 beat scan (MD 2 beat, N=135) for 61 ≤ HR ≤ 65, 3) end-systolic and mid-diastolic (37-80% of RR) 2 beat scan (ES-MD 2 beat, N=92) for 66 ≤ HR ≤ 75, 4) end-systolic (R+280-430 ms) 2 beat scan (ES 2 beat, N=21) for 76 ≤ HR ≤ 80, and 5) end-systolic (R+250-400 ms) 3 beat scan (ES 3 beat, N=22) for 81 ≤ HR ≤ 105. Image quality was classified into 3 categories (excellent (3 points), acceptable (2 points), and unacceptable (1 point)). Scanning time, DLP.e and image quality score were 1.4 ± 0.1 s, 220 ± 59 mGy·cm, 3.0 ± 0.2 points in MD 1 beat, 2.2 ± 0.2 s, 434 ± 118 mGy·cm, 2.9 ± 0.3 points in MD 2 beat, 2.1 ± 0.2 s, 729 ± 229 mGy·cm, 2.7 ± 0.5 points in ES-MD 2 beat, 1.9 ± 0.1 s, 432 ± 148 mGy·cm, 2.2 ± 0.6 points in ES 2 beat, and 2.4 ± 0.2 s, 669 ± 152 mGy·cm, 2.3 ± 0.6 points in ES 3 beat respectively. In conclusion, the prospective ECG-gated scan protocol for coronary 320-ADCT angiography in any HR group was considered reasonable and proper for image quality and radiation dose. |
| File Format | PDF HTM / HTML |
| DOI | 10.6009/jjrt.67.1398 |
| PubMed reference number | 22104231 |
| Journal | Medline |
| Volume Number | 67 |
| Issue Number | 11 |
| Alternate Webpage(s) | https://www.jstage.jst.go.jp/article/jjrt/67/11/67_11_1398/_pdf/-char/ja |
| Alternate Webpage(s) | https://doi.org/10.6009/jjrt.67.1398 |
| Journal | Nihon Hoshasen Gijutsu Gakkai zasshi |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |