Loading...
Please wait, while we are loading the content...
Similar Documents
Design and Development of Multi-Channel Data Logger for Built Environment
| Content Provider | Semantic Scholar |
|---|---|
| Author | Kumar, Anuj Singh, Inderpreet |
| Copyright Year | 2010 |
| Abstract | In this paper, an effort has been made to design and developed a 4-channel data logger for indoor environment. Initially the present work has concentrated to environmental parameter (temperature and humidity) and more polluted contaminants (concentration level of CO and CO2). The Data logger is proposed to be developed with the use of microcontroller PIC 18F4458 (inbuilt 8 channel ADC), i.e. 4 channels will be used and 4 channel will open in external sensor. Real Time Clock is also interfaced for sampled data with the instance of sampling time and month/date/year. The sampled data will be stored in the EEPROM which is interfaced to the microcontroller. The data will be stored in the note pad tabular form corresponding to the Month/Date/Year with the help of graphical user interface. Index Terms—GUI (Graphical User Interface), RTC (Real Time Clock), ADC (Analog Digital Converter). |
| File Format | PDF HTM / HTML |
| Alternate Webpage(s) | http://www.iaeng.org/publication/IMECS2010/IMECS2010_pp993-998.pdf |
| Language | English |
| Access Restriction | Open |
| Content Type | Text |
| Resource Type | Article |