Loading...
			
			Please wait, while we are loading the content...
Similar Documents
Accuracy of Image-Guided Surgical Systems at the Lateral Skull Base as Clinically Assessed Using Bone-Anchored Hearing Aid Posts as Surgical Targets
| Content Provider | Scilit | 
|---|---|
| Author | Balachandran, Ramya Fitzpatrick, J. Michael Labadie, Robert F. | 
| Copyright Year | 2008 | 
| Description | Journal: Otology & Neurotology Objective: Image-guided surgical (IGS) technology has been clinically available for more than a decade. To date, no acceptable standard exists for reporting the accuracy of IGS systems, especially for lateral skull base applications. We present a validation method that uses the post from bone-anchored hearing aid (BAHA) patients as a target. We then compare the accuracy of 2 IGS systems-one using laser skin-surface scanning (LSSS) and another using a noninvasive fiducial frame (FF) attached to patient via dental bite-block (DBB) for registration. Study Design: Prospective. Setting: Tertiary referral center. Patients: Six BAHA patients who had adequate dentition for creation of a DBB. Intervention(s): For each patient, a dental impression was obtained, and a customized DBB was made to hold an FF. Temporal bone computed tomographic (CT) scans were obtained with the patient wearing the DBB, FF, and a customized marker on the BAHA post. In a mock operating room, CT scans were registered to operative anatomy using 2 methods: 1) LSSS and 2) FF. Main Outcome Measure(s): For each patient and each system, the position of the BAHA marker in the CT scan and in the mock operating room (using optical measurement technology) was compared, and the distances between them are reported to demonstrate accuracy. Results: Accuracy (mean ± standard deviation) was 1.54 ± 0.63 mm for DBB registration and 3.21 ± 1.02 mm for LSSS registration. Conclusion: An IGS system using FF registration is more accurate than one using LSSS (p = 0.03, 2-sided Student's t test). BAHA patients provide a unique patient population upon which IGS systems may be validated. | 
| Related Links | http://europepmc.org/articles/pmc2684795?pdf=render https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2684795/pdf | 
| Ending Page | 1055 | 
| Page Count | 6 | 
| Starting Page | 1050 | 
| ISSN | 15317129 | 
| e-ISSN | 15374505 | 
| DOI | 10.1097/mao.0b013e3181859a08 | 
| Journal | Otology & Neurotology | 
| Issue Number | 8 | 
| Volume Number | 29 | 
| Language | English | 
| Publisher | Ovid Technologies (Wolters Kluwer Health) | 
| Publisher Date | 2008-12-01 | 
| Access Restriction | Open | 
| Subject Keyword | Journal: Otology & Neurotology Otorhinolaryngology Accuracy, Baha, Brainlab, Earmark, Fiducial System, Image-guided Surgical System, Surgical Target, Target Registration Error | 
| Content Type | Text | 
| Resource Type | Article | 
| Subject | Otorhinolaryngology Sensory Systems Neurology (clinical) | 
 
					