Pedicle Screw Placement Using Augmented Reality Surgical Navigation With Intraoperative 3D Imaging
| Content Provider | Scilit |
|---|---|
| Author | Elmi-Terander, Adrian Burström, Gustav Nachabe, Rami Skulason, Halldor Pedersen, Kyrre Fagerlund, Michael Ståhl, Fredrik Charalampidis, Anastasios Söderman, Michael Holmin, Staffan Babic, Drazenko Jenniskens, Inge Edström, Erik Gerdhem, Paul |
| Copyright Year | 2019 |
| Description | Journal: Spine Prospective observational study. The aim of this study was to evaluate the accuracy of pedicle screw placement using augmented reality surgical navigation in a clinical trial. Recent cadaveric studies have shown improved accuracy for pedicle screw placement in the thoracic spine using augmented reality surgical navigation with intraoperative 3D imaging, without the need for peri-procedural X-ray. In this clinical study, we used the same system to place pedicle screws in the thoracic and lumbosacral spine of 20 patients. The study was performed in a hybrid operating room with an integrated augmented reality surgical navigation system encompassing a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Three independent reviewers assessed screw placement accuracy using the Gertzbein grading on 3D scans obtained prior to wound closure. In addition, the navigation time per screw placement was measured. One orthopedic spinal surgeon placed 253 lumbosacral and thoracic pedicle screws on 20 consenting patients scheduled for spinal fixation surgery. An overall accuracy of 94.1% of primarily thoracic pedicle screws was achieved. No screws were deemed severely misplaced (Gertzbein grade 3). Fifteen (5.9%) screws had 2–4 mm breach (Gertzbein grade 2), occurring in scoliosis patients only. Thirteen of those fifteen screws were larger than the pedicle in which they were placed. Two medial breaches were observed and thirteen were lateral. Thirteen of the grade 2 breaches were in the thoracic spine. The average screw placement time was 5.2 ± 4.1 min. During the study, no device-related adverse event occurred. Augmented reality surgical navigation can be clinically used to place thoracic and lumbosacral pedicle screws with high accuracy and with acceptable navigation time. Consequently, the risk for revision surgery and complications could be minimized. Level of Evidence: 3. |
| Related Links | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6426349/pdf |
| Ending Page | 525 |
| Page Count | 9 |
| Starting Page | 517 |
| ISSN | 03622436 |
| e-ISSN | 15281159 |
| DOI | 10.1097/brs.0000000000002876 |
| Journal | Spine |
| Issue Number | 7 |
| Volume Number | 44 |
| Language | English |
| Publisher | Ovid Technologies (Wolters Kluwer Health) |
| Publisher Date | 2019-04-01 |
| Access Restriction | Open |
| Subject Keyword | Journal: Spine Augmented Reality Image-guided Surgery Intraoperative 3d Cone Beam Computed Tomography Imaging Pedicle Screw Accuracy |
| Content Type | Text |
| Resource Type | Article |
| Subject | Orthopedics and Sports Medicine Neurology (clinical) Sports Science |