Loading...
Please wait, while we are loading the content...
Similar Documents
Hemodynamic Effects of Ephedrine, Phenylephrine, and the Coadministration of Phenylephrine with Oxytocin during Spinal Anesthesia for Elective Cesarean Delivery
| Content Provider | Scilit |
|---|---|
| Author | Dyer, Robert A. Reed, Anthony R. van Dyk, Dominique Arcache, Michelle J. Hodges, Owen Lombard, Carl Greenwood, Jaime James, Michael F. |
| Copyright Year | 2009 |
| Description | Journal: Anesthesiology Background Hemodynamic responses to vasopressors used during spinal anesthesia for elective Cesarean delivery, have not been well described. This study compared the effects of bolus phenylephrine and ephedrine on maternal cardiac output (CO). The hypothesis was that phenylephrine, but not ephedrine, decreases CO when administered in response to hypotension during spinal anesthesia. Methods Forty-three patients were randomized to receive 80 microg of phenylephrine or 10 mg of ephedrine. Both pulse wave form analysis and transthoracic bioimpedance changes were used to estimate stroke volume in each patient. Hemodynamic responses to spinal anesthesia and oxytocin were also recorded. A subgroup of 20 patients was randomized to receive oxytocin compared with oxytocin plus 80 microg of phenylephrine after delivery. Results Mean CO and maximum absolute response in CO were significantly lower during the 150 s after phenylephrine administration than after ephedrine (6.2 vs. 8.1 l/min, P = 0.001, and 5.2 vs. 9.0 l/min, P < 0.0001, respectively for pulse wave form analysis, and 5.2 vs. 6.3 l/min, P = 0.01 and 4.5 vs. 6.7 l/min, P = 0.0001, respectively for bioimpedance changes). CO changes correlated with heart rate changes. Coadministration of phenylephrine obtunded oxytocin-induced decreases in systemic vascular resistance and increases in heart rate and CO. Trends in CO change were similar using either monitor. Conclusions Bolus phenylephrine reduced maternal CO, and decreased CO when compared with ephedrine during elective spinal anesthesia for Cesarean delivery. CO changes correlated with heart rate changes after vasopressor administration, emphasizing the importance of heart rate as a surrogate indicator of CO. Coadministered phenylephrine obtunded hemodynamic responses to oxytocin. |
| Related Links | http://anesthesiology.pubs.asahq.org/data/journals/jasa/931088/0000542-200910000-00017.pdf http://anesthesiology.pubs.asahq.org/data/Journals/JASA/931088/0000542-200910000-00017.pdf |
| Ending Page | 765 |
| Page Count | 13 |
| Starting Page | 753 |
| ISSN | 00033022 |
| e-ISSN | 15281175 |
| DOI | 10.1097/aln.0b013e3181b437e0 |
| Journal | Anesthesiology |
| Issue Number | 4 |
| Volume Number | 111 |
| Language | English |
| Publisher | Ovid Technologies (Wolters Kluwer Health) |
| Publisher Date | 2009-10-01 |
| Access Restriction | Open |
| Subject Keyword | Journal: Anesthesiology Coadministration of Phenylephrine Spinal Anesthesia Bolus Phenylephrine |
| Content Type | Text |
| Resource Type | Article |
| Subject | Anesthesiology and Pain Medicine |