Loading...
Please wait, while we are loading the content...
Similar Documents
The impact of audiovisual biofeedback on 4D functional and anatomic imaging: Results of a lung cancer pilot study
| Content Provider | Scilit |
|---|---|
| Author | Yang, Jaewon Yamamoto, Tokihiro Pollock, Sean Berger, Jonathan Diehn, Maximilian Graves, Edward E. Loo, Billy W. Keall, Paul J. |
| Copyright Year | 2016 |
| Description | Journal: Radiotherapy and Oncology Background and purpose The impact of audiovisual (AV) biofeedback on four dimensional (4D) positron emission tomography (PET) and 4D computed tomography (CT) image quality was investigated in a prospective clinical trial (NCT01172041). Material and methods 4D-PET and 4D-CT images of ten lung cancer patients were acquired with AV biofeedback (AV) and free breathing (FB). The 4D-PET images were analyzed for motion artifacts by comparing 4D to 3D PET for gross tumor volumes $(GTV_{PET}$) and maximum standardized uptake values $(SUV_{max}$). The 4D-CT images were analyzed for artifacts by comparing normalized cross correlation-based scores (NCCS) and quantifying a visual assessment score (VAS). A Wilcoxon signed-ranks test was used for statistical testing. Results The impact of AV biofeedback varied widely. Overall, the 3D to 4D decrease of $GTV_{PET}$ was $1.2±1.3cm^{3}$ with AV and $0.6±1.8cm^{3}$ for FB. The 4D-PET increase of $SUV_{max}$ was 1.3±0.9 with AV and 1.3±0.8 for FB. The 4D-CT NCCS were 0.65±0.27 with AV and 0.60±0.32 for FB (p=0.08). The 4D-CT VAS was 0.0±2.7. Conclusion This study demonstrated a high patient dependence on the use of AV biofeedback to reduce motion artifacts in 4D imaging. None of the hypotheses tested were statistically significant. Future development of AV biofeedback will focus on optimizing the human–computer interface and including patient training sessions for improved comprehension and compliance. |
| Related Links | https://ses.library.usyd.edu.au/bitstream/2123/18559/2/Yang_2016_Green.pdf http://www.thegreenjournal.com/article/S0167814016311197/pdf |
| Ending Page | 272 |
| Page Count | 6 |
| Starting Page | 267 |
| ISSN | 01678140 |
| e-ISSN | 18790887 |
| DOI | 10.1016/j.radonc.2016.05.016 |
| Journal | Radiotherapy and Oncology |
| Issue Number | 2 |
| Volume Number | 120 |
| Language | English |
| Publisher | Elsevier BV |
| Publisher Date | 2016-05-31 |
| Access Restriction | Open |
| Subject Keyword | Journal: Radiotherapy and Oncology Motion Management Audiovisual Biofeedback Lung Cancer 4d Pet 4d Ct |
| Content Type | Text |
| Resource Type | Article |
| Subject | Radiology, Nuclear Medicine and Imaging Hematology Oncology |