Loading...
Please wait, while we are loading the content...
Similar Documents
Potential errors in relative dose measurements in kilovoltage photon beams due to polarity effects in plane-parallel ionisation chambers
| Content Provider | Scilit |
|---|---|
| Author | Dowdell, S. Tyler, M. McNamara, J. Sloan, K. Ceylan, A. Rinks, A. |
| Copyright Year | 2016 |
| Description | Journal: Physics in Medicine & Biology Plane-parallel ionisation chambers are regularly used to conduct relative dosimetry measurements for therapeutic kilovoltage beams during commissioning and routine quality assurance. This paper presents the first quantification of the polarity effect in kilovoltage photon beams for two types of commercially available plane-parallel ionisation chambers used for such measurements. Measurements were performed at various depths along the central axis in a solid water phantom and for different field sizes at 2 cm depth to determine the polarity effect for PTW Advanced Markus and Roos ionisation chambers (PTW-Freiburg, Germany). Data was acquired for kilovoltage beams between 100 kVp (half-value layer (HVL) = 2.88 mm Al) and 250 kVp (HVL = 2.12 mm Cu) and field sizes of 3–15 cm diameter for 30 cm focus-source distance (FSD) and 4 × 4 $cm^{2}$–20 × 20 $cm^{2}$ for 50 cm FSD. Substantial polarity effects, up to 9.6%, were observed for the Advanced Markus chamber compared to a maximum 0.5% for the Roos chamber. The magnitude of the polarity effect was observed to increase with field size and beam energy but was consistent with depth. The polarity effect is directly influenced by chamber design, with potentially large polarity effects for some plane-parallel ionisation chambers. Depending on the specific chamber used, polarity corrections may be required for output factor measurements of kilovoltage photon beams. Failure to account for polarity effects could lead to an incorrect dose being delivered to the patient. |
| Related Links | http://iopscience.iop.org/article/10.1088/0031-9155/61/23/8395/pdf |
| Ending Page | 8407 |
| Page Count | 13 |
| Starting Page | 8395 |
| ISSN | 00319155 |
| e-ISSN | 13616560 |
| DOI | 10.1088/0031-9155/61/23/8395 |
| Journal | Physics in Medicine & Biology |
| Issue Number | 23 |
| Volume Number | 61 |
| Language | English |
| Publisher | IOP Publishing |
| Publisher Date | 2016-11-15 |
| Access Restriction | Open |
| Subject Keyword | Journal: Physics in Medicine & Biology Radiology, Nuclear Medicine and Imaging Ionisation Chambers Kilovoltage Beams Polarity Effects for Some Plane Effects in Plane Parallel Measurements of Kilovoltage |
| Content Type | Text |
| Resource Type | Article |
| Subject | Radiology, Nuclear Medicine and Imaging Radiological and Ultrasound Technology |