Loading...
Please wait, while we are loading the content...
Similar Documents
Development and analytical performance evaluation of an automated chemiluminescent immunoassay for pro-gastrin releasing peptide (ProGRP)
| Content Provider | Scilit |
|---|---|
| Author | Yoshimura, Toru Fujita, Kenju Kinukawa, Hideki Matsuoka, Yoshiharu Patil, Rahul D. Beligere, Gangamani S. Chan, Sabrina S. Dowell, Barry L. Sokoll, Lori Elliott, Debra Chan, Daniel W. Scheuer, Cornelia Hofmann, Karin Stieber, Petra Sakurai, Yousuke Iizuka, Masayuki Saegusa, Haruhisa Yamaguchi, Ken |
| Copyright Year | 2009 |
| Abstract | Background: Pro-gastrin releasing peptide (ProGRP) concentrations in blood play an important role in the diagnosis and treatment of patients with small cell lung cancer (SCLC). The automated quantitative ARCHITECT® ProGRP assay was developed to aid in the differential diagnosis and in the management of SCLC. The purpose of this study was to evaluate the analytical performance of this chemiluminescent microparticle immunoassay at multiple sites. Methods: ARCHITECT ProGRP measures ProGRP using a two-step sandwich using monoclonal anti-ProGRP antibodies coated on paramagnetic microparticles and labeled with acridinium. Analytical performance of the assay was evaluated at four sites: Abbott Japan, Denka Seiken, the Johns Hopkins University, and the University of Munich. Results: Total precision (%CV) for nine analyte concentrations was between 2.2 and 5.7. The analytical sensitivity of the assay was between 0.20 pg/mL and 0.88 pg/mL. The functional sensitivity at 20% CV was between 0.66 pg/mL and 1.73 pg/mL. The assay was linear up to 50,000 pg/mL using a 1:10 autodilution protocol. The calibration curve was stable for 30 days. Comparison with the Fujirebio microtiter plate enzyme-linked immunosorbent assay (EIA) ProGRP assay gave a slope of 0.93 and a correlation coefficient (r) of 0.99. Conclusions: These results demonstrate that the ARCHITECT ProGRP assay has excellent sensitivity, precision, and correlation to a reference method. This assay provides a convenient automated method for ProGRP measurement in serum and plasma in hospitals and clinical laboratories. Clin Chem Lab Med 2009;47:1557–63.Peer Reviewe |
| Related Links | https://epub.ub.uni-muenchen.de/17740/1/cclm.2009.333.pdf |
| Ending Page | 1563 |
| Page Count | 7 |
| Starting Page | 1557 |
| ISSN | 14346621 |
| e-ISSN | 14374331 |
| DOI | 10.1515/cclm.2009.333 |
| Journal | Clinical Chemistry and Laboratory Medicine (CCLM) |
| Issue Number | 12 |
| Volume Number | 47 |
| Language | English |
| Publisher | Walter de Gruyter GmbH |
| Publisher Date | 2009-01-01 |
| Access Restriction | Open |
| Subject Keyword | Clinical Chemistry and Laboratory Medicine (cclm) Medical Laboratory Technology Automated Immunoassay Chemiluminescent Microparticle Immunoassay Pro-gastrin Releasing Peptide Small Cell Lung Cancer Tumor Marker Journal: Clinical Chemistry and Laboratory Medicine (CCLM), Vol- 47 |
| Content Type | Text |
| Resource Type | Article |
| Subject | Biochemistry (medical) Clinical Biochemistry |