Loading...
Please wait, while we are loading the content...
Similar Documents
Error tracking in a clinical biochemistry laboratory
| Content Provider | Scilit |
|---|---|
| Author | Szecsi, Pal Bela Ă˜dum, Lars |
| Copyright Year | 2009 |
| Abstract | Background: We report our results for the systematic recording of all errors in a standard clinical laboratory over a 1-year period. Methods: Recording was performed using a commer- cial database program. All individuals in the labora- tory were allowed to report errors. The testing processes were classified according to function, and errors were classified as pre-analytical, analytical, post-analytical, or service-related, and then further divided into descriptive subgroups. Samples were taken from hospital wards (38.6%), outpatient clinics (25.7%), general practitioners (29.4%), and other hospitals. Results: A total of 1189 errors were reported in 1151 reports during the first year, corresponding to an error rate of 1 error for every 142 patients, or 1 per 1223 tests. The majority of events were due to human errors (82.6%), and only a few (4.3%) were the result of technical errors. Most of the errors (81%) were pre- analytical. Of the remainder, 10% were analytical, 8% were post-analytical, and 1% was service-related. Nearly half of the errors (ns550) occurred with sam- ples received from general practitioners or clinical hospital wards. Identification errors were relatively common when non-technicians collected blood samples. Conclusions: Each clinical laboratory should record errors in a structured manner. A relation database is a useful tool for the recording and extraction of data, as the database can be structured to reflect the work- flow at each individual laboratory. Clin Chem Lab Med 2009;47:1253-7. |
| Related Links | https://edoc.hu-berlin.de/bitstream/18452/10581/1/cclm.2009.272.pdf |
| ISSN | 14346621 |
| e-ISSN | 14374331 |
| DOI | 10.1515/cclm.2009.272 |
| Journal | Clinical Chemistry and Laboratory Medicine (CCLM) |
| Issue Number | 10 |
| Volume Number | 47 |
| Language | English |
| Publisher | Walter de Gruyter GmbH |
| Publisher Date | 2009-01-01 |
| Access Restriction | Open |
| Subject Keyword | Clinical Chemistry and Laboratory Medicine (cclm) Medical Laboratory Technology Diagnostic Errors Medical Errors Safety Management Journal: Clinical Chemistry and Laboratory Medicine (CCLM), Vol- 47 |
| Content Type | Text |
| Resource Type | Article |
| Subject | Biochemistry (medical) Clinical Biochemistry |