Loading...
Please wait, while we are loading the content...
Similar Documents
Results of primary THA using 36 mm femoral heads on first-generation highly cross-linked polyethylene in patients less than 60 years of age: Minimum 10-year follow-ups
| Content Provider | SAGE Publishing |
|---|---|
| Author | Cho, Myung-Rae Jun, Chung-Mu Kim, Kyung-Tae Song, Suk Kyun Choi, Won-Kee |
| Copyright Year | 2020 |
| Abstract | Long-term results of total hip arthroplasty (THA) using highly cross-linked polyethylene (HXLPE) and metal femoral head with more than 10 years of follow-up have already been reported. However, most studies included results with a head size of 28 mm that could affect wear rates. The aim of this study was to evaluate the results of 36-mm metallic femoral heads on first-generation HXLPE in patients less than 60 years of age with a minimum follow-up of 10 years.Methods:Retrospective analysis included 54 cases from 47 patients. The mean age at the time of surgery was 47.22 years and the mean follow-up period was 131.04 months. Porous-coated cementless acetabular cups (Trilolgy®; Zimmer Inc., Warsaw, Indiana, USA) and HXLPE acetabular liners (Longevity®; Zimmer Inc.) were used for all cases. Acetabular cup abduction angles, anteversion angles, and wear rates of liner were measured using polyWare pro 3D distal version 5.10.Results:The average modified Harris hip score at the final follow-up was 88.48 (range 80–96). Average Merle d’Aubigne and Postel score was 15.57 (range 14–18). There was no acetabular cup or femoral stem failing due to aseptic loosening. The average steady-state wear rate determined using radiographs taken at 1 year postoperatively and at the latest follow-up was 0.053 ± 0.025 mm/year. There were no statistically significant differences in liner wear rate with respect to age, variety of the femoral stem, or liner thickness.Conclusion:Results of THA with 36-mm metallic femoral heads on first-generation HXLPE in patients less than 60 years of age were satisfactory. |
| Related Links | https://journals.sagepub.com/doi/pdf/10.1177/2309499019896448?download=true |
| ISSN | 10225536 |
| Issue Number | 1 |
| Volume Number | 28 |
| Journal | Journal of Orthopaedic Surgery (OSJ) |
| e-ISSN | 23094990 |
| DOI | 10.1177/2309499019896448 |
| Language | English |
| Publisher | Sage Publications UK |
| Publisher Date | 2020-01-06 |
| Publisher Place | London |
| Access Restriction | Open |
| Rights Holder | © The Author(s) 2020 |
| Subject Keyword | highly cross-linked polyethylene 36-mm femoral head total hip arthroplasty wear |
| Content Type | Text |
| Resource Type | Article |
| Subject | Surgery |