Loading...
Please wait, while we are loading the content...
Similar Documents
Spatial coefficient of variation in pseudo-continuous arterial spin labeling cerebral blood flow images as a hemodynamic measure for cerebrovascular steno-occlusive disease: A comparative 15O positron emission tomography study
| Content Provider | SAGE Publishing |
|---|---|
| Author | Ibaraki, Masanobu Nakamura, Kazuhiro Toyoshima, Hideto Takahashi, Kazuhiro Matsubara, Keisuke Umetsu, Atsushi Pfeuffer, Josef Kuribayashi, Hideto Kinoshita, Toshibumi |
| Copyright Year | 2018 |
| Abstract | Pseudo-continuous arterial spin labeling (pCASL) is a completely non-invasive method of cerebral perfusion measurement. However, cerebral blood flow (CBF) quantification is hampered by arterial transit artifacts characterized by bright vascular signals surrounded by decreased signals in tissue regions, which commonly appear in patients with reduced cerebral perfusion pressure. The spatial coefficient of variation (CoV) of pCASL CBF images has been proposed as an alternative region-of-interest (ROI)-based hemodynamic measure to predict prolonged arterial transit time (ATT). This retrospective study investigates the utility of spatial CoV by comparison with 15O positron emission tomography (PET). For patients with cerebrovascular steno-occlusive disease (n = 17), spatial CoV was positively correlated with ATT independently measured by pulsed arterial spin labeling (r = 0.597, p < 0.001), confirming its role as an ATT-like hemodynamic measure. Comparisons with 15O PET demonstrated that spatial CoV was positively correlated with vascular mean transit time (r = 0.587, p < 0.001) and negatively correlated with both resting CBF (r = −0.541, p = 0.001) and CBF response to hypercapnia (r = −0.373, p = 0.030). ROI-based spatial CoV calculated from single time-point pCASL can potentially detect subtle perfusion abnormalities in clinical settings. |
| Related Links | https://journals.sagepub.com/doi/pdf/10.1177/0271678X18781667?download=true |
| Starting Page | 173 |
| Ending Page | 181 |
| Page Count | 9 |
| ISSN | 0271678X |
| Issue Number | 1 |
| Volume Number | 39 |
| Journal | Journal of Cerebral Blood Flow & Metabolism (JCB) |
| e-ISSN | 15597016 |
| DOI | 10.1177/0271678X18781667 |
| Language | English |
| Publisher | Sage Publications UK |
| Publisher Date | 2018-06-05 |
| Publisher Place | London |
| Access Restriction | Open |
| Rights Holder | © The Author(s) 2018 |
| Subject Keyword | Arterial transit artifact spatial coefficient of variation cerebral blood flow pseudo-continuous arterial spin labeling arterial transit time |
| Content Type | Text |
| Resource Type | Article |
| Subject | Neurology Neurology (clinical) Cardiology and Cardiovascular Medicine |