Loading...
Please wait, while we are loading the content...
Similar Documents
Reduced Radiation Exposure Protocol during Computer Tomography of the Left Atrium Prior to Catheter Ablation in Patients with Atrial Fibrillation
| Content Provider | MDPI |
|---|---|
| Author | Jadczyk, Tomasz Wolf, Jiri Pesl, Martin Soucek, Filip Lehar, Frantisek Jez, Jiri Kulik, Tomas Tyshchenko, Bohdan Belaskova, Silvie Ourednicek, Petr Caluori, Guido Novak, Miroslav Starek, Zdenek |
| Copyright Year | 2022 |
| Description | (1) Background: Computer tomography (CT) is an imaging modality used in the pre-planning of radiofrequency catheter ablation (RFA) procedure in patients with cardiac arrhythmias. However, it is associated with a considerable ionizing radiation dose for patients. This study aims to develop and validate low-dose CT scanning protocols of the left atrium (LA) for RFA guidance. (2) Methods: 68 patients scheduled for RFA of atrial fibrillation were sequentially assigned to four groups of ECG-gated scanning protocols, based on the set tube current (TC): Group A (n = 20, TC = 33 mAs), Group B (n = 18, TC = 67 mAs), Group C (n = 10, TC = 135 mAs), and control Group D (n = 20, TC = 600 mAs). We used a 256-row multidetector CT with body weight-dependent tube voltage of 80 kVp (90 kg). We evaluated scanning parameters including radiation dose, total scanning procedure time and signal-to-noise ratio (SNR). (3) Results: The average effective radiation dose (ED) was lower in Group A in comparison to Group B, C and D (0.83 (0.76–1.10), 1.55 (1.36–1.67), 2.91 (2.32–2.96) and 9.35 (8.00–10.04) mSv, p < 0.05). The total amount of contrast media was not significantly different between groups. The mean SNR was 6.5 (5.8–7.3), 7.1 (5.7–8.2), 10.8 (10.1–11.3), and 12.2 (9.9–15.7) for Group A, B, C and D, respectively. The comparisons of SNR in group A vs. B and C vs. D were without significant differences. (4) Conclusions: Optimized pre-ablation CT scanning protocols of the LA can reduce an average ED by 88.7%. Three dimensional (3D) models created with the lowest radiation protocol are useful for the integration of electro-anatomic-guided RFA procedures. |
| Starting Page | 612 |
| e-ISSN | 20754418 |
| DOI | 10.3390/diagnostics12030612 |
| Journal | Diagnostics |
| Issue Number | 3 |
| Volume Number | 12 |
| Language | English |
| Publisher | MDPI |
| Publisher Date | 2022-03-01 |
| Access Restriction | Open |
| Subject Keyword | Diagnostics Radiology, Nuclear Medicine and Imaging Computed Tomography Catheter Ablation Radiation |
| Content Type | Text |
| Resource Type | Article |