Cable bundle wire derating
| Content Provider | NASA Technical Reports Server (NTRS) |
|---|---|
| Author | Lundquist, Ray A. Leidecker, Henning |
| Copyright Year | 1998 |
| Description | The allowable operating currents of electrical wiring when used in the space vacuum environment is predominantly determined by the maximum operating temperature of the wire insulation. For Kapton insulated wire this value is 200 C. Guidelines provided in the Goddard Space Flight Center (GSFC) Preferred Parts List (PPL) limit the operating current of wire within vacuum to ensure the maximum insulation temperature is not exceeded. For 20 AWG wire, these operating parameters are: (1) 3.7 amps per wire; (2) bundle of 15 or more wires; (3) 70 C environment: and (4) vacuum of 10(exp -5) torr or less. To determine the behavior and temperature of electrical wire at different operating conditions, a thermal vacuum test was performed on a representative electrical harness of the Hubble Space Telescope (HST) power distribution system. This paper describes the test and the results. |
| File Size | 376215 |
| Page Count | 9 |
| File Format | |
| Alternate Webpage(s) | http://archive.org/details/NASA_NTRS_Archive_19990113164 |
| Archival Resource Key | ark:/13960/t4dn92z2x |
| Language | English |
| Publisher Date | 1998-01-01 |
| Access Restriction | Open |
| Subject Keyword | Electronics And Electrical Engineering Wiring Insulation Kapton Trademark Vacuum Thermal Vacuum Tests Lists Hubble Space Telescope Wire Current Density Bundles Operating Temperature Harnesses Ntrs Nasa Technical Reports Server (ntrs) Nasa Technical Reports Server Aerodynamics Aircraft Aerospace Engineering Aerospace Aeronautic Space Science |
| Content Type | Text |
| Resource Type | Article |