Loading...
Please wait, while we are loading the content...
Description of the insulation system for the langley 0.3-meter transonic cryogenic tunnel
| Content Provider | NASA Technical Reports Server (NTRS) |
|---|---|
| Author | Lawing, P. L. Dress, D. A. Kilgore, R. A. |
| Copyright Year | 1985 |
| Description | The thermal insulation system of the Langley 0.3 Meter Transonic Cryogenic Tunnel is described. The insulation system is designed to operate from room temperature down to about 77.4 K, the temperature of liquid nitrogen at 1 atmosphere. A detailed description is given of the primary insulation sytem consists of glass fiber mats, a three part vapor barrier, and a dry positive pressure purge system. Also described are several secondary insulation systems required for the test section, actuators, and tunnel supports. An appendix briefly describes the original insulation system which is considered inferior to the one presently in place. The time required for opening and closing portions of the insulation system for modification or repair to the tunnel has been reduced, typically, from a few days for the original thermal insulating system to a few hours for the present system. |
| File Size | 12312253 |
| File Format | |
| Language | English |
| Publisher Date | 1985-01-01 |
| Access Restriction | Open |
| Subject Keyword | Research And Support Facilities (air) Transonic Wind Tunnels Liquid Nitrogen Thermal Insulation Purging Wind Tunnel Apparatus Safety Design Analysis Cryogenic Wind Tunnels Ntrs Nasa Technical Reports ServerĀ (ntrs) Nasa Technical Reports Server Aerodynamics Aircraft Aerospace Engineering Aerospace Aeronautic Space Science |
| Content Type | Text |
| Resource Type | Technical Report |