| Description | The flight models of the active radiation detector (ARD) for the ENV-01 environmental monitor were calibrated using gamma radiation. Measured sensitivities of the ion chambers were 6.1 + or - 0.3 micron rad per count for ARD S/N1, and 10.4 + or - 0.5 micron rad per count for ARD S/N2. Both were linear over the measured range 0.10 to 500 m/rad hour. The particle counters (proportional counters) were set to respond to approximately 85% of minimum ionizing particles of unit charge passing through them. These counters were also calibrated in the gamma field. |
| File Size | 1230819 |
| Page Count | 20 |
| File Format | |
| Alternate Webpage(s) | http://archive.org/details/NASA_NTRS_Archive_19830016562 |
| Archival Resource Key | ark:/13960/t12n9z77r |
| Language | English |
| Publisher Date | 1982-12-01 |
| Access Restriction | Open |
| Subject Keyword | Sensitivity Radiation Detectors Aerospace Environments Calibrating Exposure Spacelab Payloads Environmental Monitoring Ionization Chambers Ntrs Nasa Technical Reports ServerĀ (ntrs) Nasa Technical Reports Server Aerodynamics Aircraft Aerospace Engineering Aerospace Aeronautic Space Science |