| Description | The on-orbit performance of the Skylab refrigeration system components is presented. Flight anomalies are analyzed and performance of the newly developed components is described. Nine months of orbit data proved the practicality of the leak-free coolant system design. Flight proven application of a thermal capacitor and development test results of the first all-mechanical, low temperature mixing valve represent a significant advance in single-phase, low temperature coolant loop design. System flight data suggest that additional instrumentation and fluid filters could have prevented system orbit performance anomalies. |
| File Size | 825376 |
| Page Count | 17 |
| File Format | |
| Alternate Webpage(s) | http://archive.org/details/NASA_NTRS_Archive_19760012093 |
| Archival Resource Key | ark:/13960/t0xq1s83b |
| Language | English |
| Publisher Date | 1975-08-01 |
| Access Restriction | Open |
| Subject Keyword | Man/system Technology And Life Support Refrigerating Orbital Workshops Spacecraft Performance Spacecraft Components Postflight Analysis In-flight Monitoring Cooling Systems Skylab Program Skylab 1 Ntrs Nasa Technical Reports Server (ntrs) Nasa Technical Reports Server Aerodynamics Aircraft Aerospace Engineering Aerospace Aeronautic Space Science |