Loading...
Please wait, while we are loading the content...
Anterior Bone Loss after Cervical Baguera C Disc versus Bryan Disc Arthroplasty.
| Content Provider | Europe PMC |
|---|---|
| Author | Yang, Chih-Chang Chen, Tse-Yu Chen, Wen-Hsien Tzeng, Chung-Yuh Huang, Chih-Wei Lin, Ruei-Hong Kao, Ting-Hsien Chen, Hsien-Te Chang, Chien-Chun Tsou, Hsi-Kai |
| Copyright Year | 2023 |
| Abstract | Objectives The objectives of this study were to identify the risk factors and incidence of anterior bone loss (ABL) after Baguera C cervical disc arthroplasty (CDA) and identify whether design differences in artificial discs affect ABL. Methods In this retrospective radiological review of patients who underwent single-level Baguera C CDA in a medical center, the extent of ABL and the following radiological parameters were recorded: global and segmental alignment angle, lordotic angle (or functional spinal unit angle), shell angle, global range of motion (ROM), and ROM of the index level. ABL at the index level was grade 0-2. Grade 0 was defined as no remodeling, grade 1 as spur disappearance or mild change in body contour, and grade 2 as obvious bone regression with Baguera C Disc exposure. Results Combining grade 1 and grade 2, ABL was found in 56 upper adjacent vertebrae and 52 lower adjacent vertebrae of the 77 patients. Only 18 patients (23.4%) had no ABL. Shell angle differed significantly between ABL grades of both the upper and lower adjacent level: 0.0° in grade 0 and 1 ABL vs. 2.0° in grade 2 ABL of the upper adjacent level (p < 0.05); and 0.0° in grade 0 and 1 ABL vs. 3.5° in grade 2 ABL of the lower adjacent level (p < 0.05). A female predominance of ABL was found. Hybrid surgery and artificial disc size were also related to ABL. Conclusions ABL is more common in Baguera C Disc arthroplasty than Bryan Disc arthroplasty. Larger shell angle was related to ABL after CDA with Baguera C Discs, which may indicate that shell angle is pivotal in determining the incidence of ABL after CDA. Females had more ABL with Baguera C Disc arthroplasty; this might be related to shorter endplate lengths as well as a smaller endplate-implant mismatch. |
| ISSN | 23146133 |
| Journal | Biomed Research International |
| Volume Number | 2023 |
| PubMed Central reference number | PMC9925247 |
| PubMed reference number | 36794256 |
| e-ISSN | 23146141 |
| DOI | 10.1155/2023/8010223 |
| Language | English |
| Publisher | Hindawi |
| Publisher Date | 2023-02-06 |
| Access Restriction | Open |
| Rights License | This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Copyright © 2023 Chih-Chang Yang et al. |
| Content Type | Text |
| Resource Type | Article |
| Subject | Immunology and Microbiology Medicine Biochemistry, Genetics and Molecular Biology |