Loading...
Please wait, while we are loading the content...
Similar Documents
Evaluation of Surface Properties and Elastic Modulus of CAD-CAM Milled, 3D Printed, and Compression Moulded Denture Base Resins: An In Vitro Study.
| Content Provider | Europe PMC |
|---|---|
| Author | Zeidan, Ahmed Abd El-latif Abd Elrahim, Ramy Abdallah Abd El Hakim, Adel Fawzy Harby, Nehad Mohammed Helal, Mohamed Ahmed |
| Copyright Year | 2022 |
| Abstract | Objectives:This study evaluated the surface roughness, surface hardness, and elastic modulus of CAD-CAM (Computer-aided design/computer-aided manufacturing) milled, three-dimensional printed and conventional compression-moulded denture base resins.Materials and Methods:Thirty specimens (65*10*3 mm) were fabricated and divided into 3 groups (10 for each group) according to the type of denture base resin, Group I contained specimens of milled denture base resin, Group II contained specimens of 3-dimensional printed denture base resin, Group III contained specimens of polymethyl methacrylate heat cured denture base resin. The surface roughness of all specimens was evaluated using an atomic force microscope. Then by using the three-point bending test, the elastic modulus of the 30 specimens was evaluated. Finally, after fracturing the specimens from the bending test, the fractured specimens of the 3 groups were used to evaluate hardness using the Vickers hardness test. Data were analyzed using one-way ANOVA and Tukey’s pair-wise post hoc tests.Results:There were significant differences between the tested groups (P< 0.05). The milled denture base resins showed the lowest surface roughness (27.46 ± 5.45 nm) when compared with printed (47 ± 7.01 nm) and conventional (39.72 ± 4.72 nm) denture base resins (P< 0.05); however, there was a significant increase in elastic modulus and hardness of milled (3240.06 ± 61.23 MPa and 29.18 ± 3.44 Vickers hardness number) and conventional (3017.16 ± 215.32 MPa and 22.44 ± 0.98 Vickers hardness number) denture base resins when compared with printed denture (576.65 ± 37.73 MPa and 2.64 ± 0.37 Vickers hardness number) base resins (P< 0.05).Conclusions:Milled denture base resins showed the lowest surface roughness, and highest hardness and elastic modulus among the three groups. |
| ISSN | 22310762 |
| Journal | Journal of International Society of Preventive & Community Dentistry |
| Volume Number | 12 |
| PubMed Central reference number | PMC9912834 |
| Issue Number | 6 |
| PubMed reference number | 36777013 |
| e-ISSN | 22501002 |
| DOI | 10.4103/jispcd.JISPCD_158_22 |
| Language | English |
| Publisher | Wolters Kluwer - Medknow |
| Publisher Date | 2022-11-01 |
| Publisher Place | India |
| Access Restriction | Open |
| Rights License | This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. Copyright: © 2022 Journal of International Society of Preventive and Community Dentistry |
| Subject Keyword | 3D printing additive technique CAD-CAM denture base resin elastic modulus hardness roughness subtractive technique surface roughness |
| Content Type | Text |
| Resource Type | Article |
| Subject | Dentistry |