Loading...
Please wait, while we are loading the content...
Test-Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise.
| Content Provider | Europe PMC |
|---|---|
| Author | del-Cuerpo, Indya Jerez-Mayorga, Daniel Delgado-Floody, Pedro Morenas-Aguilar, María Dolores Chirosa-Ríos, Luis Javier |
| Editor | Tchounwou, Paul B. |
| Copyright Year | 2023 |
| Abstract | Backgroundthe main objective of this study was to evaluate the test-retest reliability of two different functional electromechanical dynamometry (FEMD)-controlled squat training protocols.Methodstwenty-eight healthy young adults volunteered to participate in this study. They attended the laboratory on four different days and performed four sessions: two of three sets of 12 repetitions at 75% 1RM and two of three sets of 30 repetitions at 50% 1RM. The range of movement (ROM), mean dynamic strength (MDS), peak dynamic strength (PDS), mean velocity (MV), peak velocity (PV), mean potency (MP), peak potency (PP), work (W), and impulse (I) were recorded. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) were obtained.Resultsreliability was very high for ROM (CV: 3.72%, ICC: 0.95), MDS (CV: 1.09%, ICC: 1.00), PDS (CV: 1.97%, ICC: 1.00), and W (CV: 4.69%, ICC: 1.00) conditions at 50% 1RM and for ROM (CV: 3.90%, ICC: 0.95), MDS (CV: 0.52, ICC: 1.00), PDS (CV: 1.49%, ICC: 0.98), and W (CV: 4.14%, ICC: 1.00) conditions at 75% 1RM and high for the rest of variables at 50 and 75% 1RM.Conclusionsthis study demonstrates that FEMD is a reliable instrument to measure ROM, MDS, PDS, MV, PV, PV, MP, MP, W, and I during both squat protocols (50 and 75% 1RM) in healthy young adults. |
| ISSN | 16617827 |
| Journal | International Journal of Environmental Research and Public Health [Int J Environ Res Public Health] |
| Volume Number | 20 |
| DOI | 10.3390/ijerph20021289 |
| PubMed Central reference number | PMC9859296 |
| Issue Number | 2 |
| PubMed reference number | 36674047 |
| e-ISSN | 16604601 |
| Language | English |
| Publisher | Molecular Diversity Preservation International (MDPI) |
| Publisher Date | 2023-01-11 |
| Access Restriction | Open |
| Subject Keyword | reproducibility muscle strength dynamometer isokinetic |
| Content Type | Text |
| Resource Type | Article |
| Subject | Health, Toxicology and Mutagenesis Pollution Public Health, Environmental and Occupational Health |