Loading...
Please wait, while we are loading the content...
Evaluation of a wrist-worn photoplethysmography monitor for heart rate variability estimation in patients recovering from laparoscopic colon resection.
| Content Provider | Europe PMC |
|---|---|
| Author | Rinne, Juha K. A. Miri, Seyedsadra Oksala, Niku Vehkaoja, Antti Kössi, Jyrki |
| Abstract | To evaluate the accuracy of heart rate variability (HRV) parameters obtained with a wrist-worn photoplethysmography (PPG) monitor in patients recovering from minimally invasive colon resection to investigate whether PPG has potential in postoperative patient monitoring. 31 patients were monitored for three days or until discharge or reoperation using a wrist-worn PPG monitor (PulseOn, Finland) with a Holter monitor (Faros 360, Bittium Biosignals, Finland) as a reference measurement device. Beat-to-beat intervals (BBI) and HRV information collected by PPG were compared with RR intervals (RRI) and HRV obtained from the ECG reference after removing artefacts and ectopic beats. The beat-to-beat mean error (ME) and mean absolute error (MAE) of good quality heartbeat intervals obtained by wrist PPG were estimated as − 1.34 ms and 10.4 ms respectively. A significant variation in the accuracy of the HRV parameters was found. In the time domain, SDNN (9.11%), TRI (11.4%) and TINN (11.1%) were estimated with low relative MAE, while RMSSD (34.3%), pNN50 (139%) and NN50 (188%) had higher errors. The logarithmic parameters in the frequency domain (VLF Log, LF Log and HF Log) exhibited the lowest relative error, and for non-linear parameters, SD2 (7.5%), DFA α1 (8.25%) and DFA α2 (4.71%) were calculated much more accurately than SD1 (34.3%). The wrist PPG shows some potential for use in a clinical setting. The accuracy of several HRV parameters analyzed post hoc was found sufficient to be used in further studies concerning postoperative recovery of patients undergoing laparoscopic colon resection, although there were large errors in many common HRV parameters such as RMSSD, pNN50 and NN50, rendering them unusable.ClinicalTrials.gov Identifier: NCT04996511, August 9, 2021, retrospectively registered |
| Related Links | https://europepmc.org/backend/ptpmcrender.fcgi?accid=PMC9852147&blobtype=pdf |
| ISSN | 13871307 |
| Journal | Journal of Clinical Monitoring and Computing [J Clin Monit Comput] |
| Volume Number | 37 |
| DOI | 10.1007/s10877-022-00854-w |
| PubMed Central reference number | PMC9852147 |
| Issue Number | 1 |
| PubMed reference number | 35394583 |
| e-ISSN | 15732614 |
| Language | English |
| Publisher | Springer Netherlands |
| Publisher Date | 2022-04-08 |
| Publisher Place | Dordrecht |
| Access Restriction | Open |
| Rights License | Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. © The Author(s) 2022 |
| Subject Keyword | Photoplethysmography PPG Holter monitor Heart rate variability Postoperative recovery Inter-beat-intervals RR intervals |
| Content Type | Text |
| Resource Type | Article |
| Subject | Critical Care and Intensive Care Medicine Anesthesiology and Pain Medicine Health Informatics |