Loading...
Please wait, while we are loading the content...
Similar Documents
Sources and components of volatile organic compounds in breast surgery operating rooms
| Content Provider | Directory of Open Access Journals (DOAJ) |
|---|---|
| Author | Ming-Huei Cheng Chi-Tsung Chen Li-Heng Pao Gwo-Hwa Wan Chun-Hui Chiu Hsu-Huan Chou |
| Abstract | Objectives: The composition and concentration distribution of volatile organic compounds (VOCs) in surgical smoke had seldomly been reported. This study aimed to investigate the profile of VOCs and their concentration in surgical smoke from breast surgery during electrocautery in different tissues, electrosurgical units, and electrocautery powers. Methods: Thirty-eight surgical smoke samples from 23 patients performed breast surgery were collected using evacuated stainless steel canisters. The concentrations of 87 VOCs in surgical smoke samples were analyzed by gas chromatography-mass spectrometry. The human tissues, electrosurgical units, and electrocautery power were recorded. Results: The median level of total VOCs concentrations in surgical smoke samples from mammary glands (total VOCs: 9953.5 ppb; benzene: 222.7 ppb; 1,3-butadiene: 856.2 ppb; vinyl chloride: 3.1 ppb) using conventional electrosurgical knives were significantly higher than that from other tissues (total VOCs: 365.7–4266.8 ppb, P < 0.05; benzene: 26.4–112 ppb, P < 0.05; 1,3-butadiene: 15.6–384 ppb, P < 0.05; vinyl chloride: 0.6–1.8 ppb, P < 0.05) using different electrosurgical units. A high methanol concentration was found in surgical smoke generated during breast surgery (641.4–4452.5 ppb) using different electrosurgical units. An electrocautery power of ≥ 27.5 watts used for skin tissues produced a higher VOCs concentration (2905.8 ppb). Conclusions: The surgical smoke samples collected from mammary glands using conventional electrosurgical knives had high VOCs concentrations. The carcinogens (including benzene, 1,3-butadiene, and vinyl chloride) and methanol were found in the surgical smoke samples from different electrosurgical units. The type of electrosurgical unit and electrocautery power used affected VOCs concentrations in surgical smoke. |
| Related Links | http://www.sciencedirect.com/science/article/pii/S0147651320316912 |
| ISSN | 01476513 |
| e-ISSN | 10902414 |
| DOI | 10.1016/j.ecoenv.2020.111855 |
| Journal | Ecotoxicology and Environmental Safety |
| Volume Number | 209 |
| Language | English |
| Publisher | Elsevier |
| Publisher Date | 2021-01-01 |
| Publisher Place | United States |
| Access Restriction | Open |
| Subject Keyword | Environmental Pollution Environmental Sciences Surgical Smoke Breast Surgery Electrosurgical Units Electrocautery Power Volatile Organic Compounds |
| Content Type | Text |
| Resource Type | Article |
| Subject | Pollution Health, Toxicology and Mutagenesis Public Health, Environmental and Occupational Health |