DESIGN CONSIDERATION TO PPM KLYSTRONS FOR INDUSTRIAL LINAC
| Content Provider | CiteSeerX |
|---|---|
| Author | Yano, Atsunori Ohkubo, Yoshihisa |
| Abstract | Toshiba has been developing the C-band and X-band Periodic Permanent Magnet (PPM) focused klystron in collaboration with KEK and manufactured prototypes for the JLC project. [1] The PPM klystron has an advantage to enhance the total efficiency as a result of eliminating the electric power for the focusing magnet. From experience on the development the PPM focused klystrons for the JLC project, we plan to apply the PPM focused klystron to the medical and industrial linac. The periodic magnet focusing scheme has some technical difficulties such as stop band voltage. To design the PPM klystron for the medical and industrial linac, it is necessary to give heed to electron beam instability; so that the tube parameters of the PPM focused klystrons have some constraints. The size of the accelerator system is substantially reduced if a PPM focused klystron is used. The majority of medical and industrial linacs use frequencies of S-band range. We discuss the availability of the S-band PPM focused klystron in this paper. |
| File Format | |
| Access Restriction | Open |
| Subject Keyword | Beam Instability Technical Difficulty Jlc Project Ppm Klystron Industrial Linac Total Efficiency X-band Periodic Permanent Magnet Tube Parameter S-band Ppm Industrial Linac Use Frequency Electric Power Ppm Focused Klystron Periodic Magnet Stop Band Voltage Focusing Magnet S-band Range Accelerator System |
| Content Type | Text |