Author | Ramos, Helena Pereira, M. Viegas, V. Girão, P. |
Abstract | Abstract – The paper reports the tests conducted on a dedicated Transducer Independent Interface (TII) to check its compliance with standard IEEE 1451.2 specifications. The interface was built using a synchronous data transfer based on the Serial Peripheral Interface (SPI) protocol integrated in a PIC microcontroller used as the Smart Transducer Interface Module (STIM) and the Centronics port of the PC, used as the Network Capable Application Processor (NCAP’s TII port). The description of each line and the connections are also presented. The working prototype of the STIM controlled by a NCAP module was implemented to connect several transducers without communication capabilities used in a water quality monitoring network. The NCAP, also described in the paper, is emulated in a PC and it was fully developed using LabVIEW 6.1 I. |
File Format | |
Access Restriction | Open |
Subject Keyword | Centronics Based Transducer Independent Interface Fully Compliant Network Capable Application Processor Synchronous Data Transfer Dedicated Transducer Independent Interface Communication Capability Serial Peripheral Interface Tii Port Smart Transducer Interface Module Ncap Module Standard Ieee Several Transducer Centronics Port Water Quality Monitoring Network Pic Microcontroller |
Content Type | Text |